Robust detection of heart beats in multimodal data
Related Experiment Video
Updated: Apr 6, 2026

Semi-automated Optical Heartbeat Analysis of Small Hearts
Published on: September 16, 2009
Ikaro Silva1, Benjamin Moody1, Joachim Behar2,3
1Institute for Medical Engineering and Science, Massachusetts Institute of Technology, 77 Massachusetts Ave, Cambridge, MA 02139, USA.
Abstract:
This editorial reviews the background issues, the design, the key achievements, and the follow-up research generated as a result of the PhysioNet/Computing in Cardiology (CinC) Challenge 2014, published in the concurrent focus issue of Physiological Measurement. Our major focus was to accelerate the development and facilitate the comparison of robust methods for locating heart beats in long-term multi-channel recordings. A public (training) database consisting of 151 032 annotated beats was compiled from records that contained ECGs as well as pulsatile signals that directly reflect cardiac activity, and other signals that may have few or no observable markers of heart beats. A separate hidden test data set (consisting of 152 478 beats) is permanently stored at PhysioNet, and a public framework has been developed to provide researchers with the ability to continue to automatically score and compare the performance of their algorithms. A scoring criteria based on the averaging of gross sensitivity, gross positive predictivity, average sensitivity, and average positive predictivity is proposed. The top three scores (as of March 2015) on the hidden test data set were 93.64%, 91.50%, and 90.70%.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring pulse
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...