Related Experiment Video
Updated: Apr 6, 2026

Single Liposome Measurements for the Study of Proton-Pumping Membrane Enzymes Using Electrochemistry and Fluorescent Microscopy
Published on: February 21, 2019
Voltammetric detection and profiling of isoprenoid quinones hydrophobically transferred from bacterial cells
Dung Quynh Le1, Aya Morishita1, Shiho Tokonami1
1†Department of Applied Chemistry, Osaka Prefecture University, 1-2 Gakuen, Naka, Sakai, Osaka 599-8570, Japan.
Abstract:
We have developed a novel bacterial detection technique by desiccating a bacterial suspension deposited on an electrode. It was also found that the use of an indium-tin-oxide (ITO) electrode dramatically improved the resolution of the voltammogram, allowing us to observe two pairs of redox peaks, each assigned to the adsorption of isoprenoid ubiquinone (UQn) and menaquinone (MKn), which were present in the bacterial cell envelopes, giving midpeak potentials of -0.015 and -0.25 V versus Ag|AgCl|saturated KCl| at pH 7.0, respectively. Most of the microorganisms classified in both the Gram-negative and -positive bacteria gave well-defined redox peaks, demonstrating that this procedure made the detection of the quinones possible without solvent extraction. It has been demonstrated that the present technique can be used not only for the detection of bacteria, but also for profiling of the isoprenoid quinones, which play important roles in electron and proton transfer in microorganisms. In this respect, the present technique provides a much more straightforward way than the solvent extraction in that one sample can be prepared in 1 min by heat evaporation of a suspension containing the targeted bacteria, which has been applied on the ITO electrode.
Related Concept Videos
Oxidation of Phenols to Quinones
o-hydroxy phenols are oxidized to o-quinones and p-hydroxy phenols to p-quinones. Such redox reactions involve the transfer of two electrons and two protons. The reversible redox...
Voltammetric Techniques: Cyclic Voltammetry
Voltammetric Techniques: Pulse Voltammetry
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...