Assessment of Pharmaceutical Powder Flowability using Shear Cell-Based Methods and Application of Jenike's

Paul D Jager1, Tommasina Bramante1, Paul E Luner1

  • 1Material and Analytical Sciences, Boehringer Ingelheim Pharmaceuticals, Inc., Ridgefield, Connecticut 06877.

Related Concept Videos

In Vitro Drug Dissolution: Compendial Testing Models II01:09

In Vitro Drug Dissolution: Compendial Testing Models II

Various dissolution methods are utilized to assess a drug’s dissolution rate, including the flow-through cell, paddle-over-disk, cylinder, and reciprocating disk methods.The flow-through cell apparatus (USP (United States Pharmacopeia) method 4) comprises a reservoir for the dissolution medium and a pump that propels the medium through the cell containing the test sample. This method is crucial for assessing modified-release dosage forms with minimally soluble active ingredients,...
572
In Vitro Drug Dissolution: Alternative Methods01:17

In Vitro Drug Dissolution: Alternative Methods

Alternative drug dissolution methods include the rotating bottle, intrinsic dissolution test, peristalsis, and the Franz diffusion cell method. The rotating bottle method involves meticulously rotating tightly capped controlled-release beads in a temperature-controlled bath. Periodic decanting of samples allows for residue assay, followed by refilling with fresh medium and testing at various pH levels to emulate the gastrointestinal tract conditions.In contrast, the intrinsic dissolution test...
351
In Vitro Drug Dissolution: Compendial Testing Models I01:13

In Vitro Drug Dissolution: Compendial Testing Models I

Compendial dissolution methods are standardized procedures defined by pharmacopeias to evaluate the rate at which a drug dissolves in a specific medium. These methods ensure batch-to-batch consistency, enable quality control, and support the prediction of drug bioavailability. They are critical for both immediate and modified-release drug products.The apparatuses used for dissolution testing differ in their design and mechanical function, but all aim to simulate the physiological environment of...
500
Flow Cytometry01:23

Flow Cytometry

The development of flow cytometry techniques began in 1934 with initial attempts by Andrew Moldavan, a bacteriologist who counted the cells in a flowing capillary system. Moldavan pumped cells through a capillary tube focused under a microscope for visualization. The invention of photometry allowed the measurement of differentially-stained cells, and Louis Kamentsky developed the first multiparameter flow cytometer in 1965 to identify and count the cancer cells in cervical tissue specimens.
In...
17.5K