Comparative Evaluation of Push Out Bond Strength of a Fiber Post System using Four Different Resin Cements: An
Anshuraj Kopal Ashok Kumar Das1, B C Muddugangadhar2, G S Amarnath3
1Post-graduate Student, Department of Prosthodontics including Crown and Bridge and Implantology, M R Ambedkar Dental College and Hospital, Bengaluru, Karnataka, India.
Background:
Debonding is one of the frequent causes of failure experienced in fiber-reinforced composite posts, and establish along post space-dentin adhesive interface. The purpose of this study was to assess push-out bond strength of a fiber-reinforced post system using four different resin cements.
Materials And Methods:
In this in-vitro study 40 mandibular premolars were decoronated, and roots were treated endodontically. Following the post space preparation, the roots were grouped into four groups of 10 specimens each. Fiber-reinforced composite posts were cemented with four resin cement systems: (a) Multilink Speed, (b) Rely X Unicem, (c) Calibra, and (d) Permaflo DC. Three sections of each root, with a thickness of 3 mm, were prepared. The push-out test was with a universal testing machine at a crosshead speed of 1 mm/min, and bond strength values were evaluated. The data were analyzed with using multivariate analysis of variance (MANOVA) and post-hoc Scheffe test.
Result:
The mean push-out bond strength was highest for Rely X Unicem (18.0 ± 1.81), followed by Multilink Speed (13.1 ± 0.75) and Permaflo DC (12.8 ± 0.95). The lowest mean push-out bond strength was seen with Calibra (11.8 ± 0.69). There were statistically significant differences seen in the push-out bond strength of resin cement in different root canal regions using MANOVA and post-hoc Scheffe test.
Conclusion:
Mean push-out bond strength was highest for Rely X Unicem, followed by Multilink Speed and Permaflo DC. Lowest mean push-out bond strength was seen with respect to Calibra.
More Related Videos
Related Concept Videos
Bonding and Strength of Aggregate
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Impact Strength of Concrete
Fiber Reinforced Concrete
Mortar Properties
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...