Neutral-carrier ion-selective electrodes assessed by the Nernst-Planck-Poisson model

Jerzy J Jasielec1, Tomasz Sokalski2, Robert Filipek1

  • 1Faculty of Materials Science and Ceramics, AGH-University of Science and Technology , Al. Mickiewicza 30, 30059 Cracow, Poland.

Analytical Chemistry
|August 5, 2015
PubMed

Related Concept Videos

Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
2.3K
Processes at Electrodes01:30

Processes at Electrodes

The electrode interacts with ions in the electrolyte solution at its interface. The rate of oxidation and reduction depends on the speed at which electrons can transfer through this interface. As ions attach to or leave the electrode surface, the electrode acquires a charge, and an electrical potential forms across the interface, making the process more difficult to reach equilibrium. The charge on the electrode affects the local ion concentrations in the solution, though thermal motion...
80
The Electrical Double Layer01:30

The Electrical Double Layer

In the region where two bulk phases meet, an intricate electric charge distribution arises due to charge transfer, ion adsorption, molecular orientation, and charge distortion. This complex distribution is commonly referred to as the electrical double layer.When a solid electrode interfaces with ions in an electrolyte solution, the speed of electron transfer dictates the rates of oxidation and reduction. The electrode acquires a charge through the escape of atoms into the solution as cations or...
173
Ion Exchange01:17

Ion Exchange

Ion exchange chromatography separates charged molecules from a solution by reversibly exchanging them with mobile, or 'active', ions associated with the oppositely charged stationary phase. This method can be used to separate ions, soften and deionize water, and purify solutions. The polymers comprising the ion-exchange column are high-molecular-weight and chemically stable polymers, crosslinked to be porous and essentially insoluble. They are also functionalized with either acidic or...
1.6K
The Nernst Equation02:59

The Nernst Equation

Nonstandard Reaction Conditions
The interconnection between standard cell potentials and various thermodynamic parameters such as the standard free energy change ΔG° and equilibrium constant K has been previously explored. For example, a redox reaction involving zinc(II) and tin(II) ions at 1 M concentration with Eºcell = +0.291 V and ΔG° = −56.2 kJ is spontaneous.
48.8K
Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
2.9K