A novel curve fitting method for AV optimisation of biventricular pacemakers
Hakim-Moulay Dehbi1, Siana Jones, S M Afzal Sohaib
1Department of Epidemiology and Biostatistics, Imperial College London, London W2 1PG, UK.
None:
In this study, we designed and tested a new algorithm, which we call the 'restricted parabola', to identify the optimum atrioventricular (AV) delay in patients with biventricular pacemakers. This algorithm automatically restricts the hemodynamic data used for curve fitting to the parabolic zone in order to avoid inadvertently selecting an AV optimum that is too long.We used R, a programming language and software environment for statistical computing, to create an algorithm which applies multiple different cut-offs to partition curve fitting of a dataset into a parabolic and a plateau region and then selects the best cut-off using a least squares method. In 82 patients, AV delay was adjusted and beat-to-beat systolic blood pressure (SBP) was measured non-invasively using our multiple-repetition protocol. The novel algorithm was compared to fitting a parabola across the whole dataset to identify how many patients had a plateau region, and whether a higher hemodynamic response was achieved with one method.In 9/82 patients, the restricted parabola algorithm detected that the pattern was not parabolic at longer AV delays. For these patients, the optimal AV delay predicted by the restricted parabola algorithm increased SBP by 1.36 mmHg above that predicted by the conventional parabolic algorithm (95% confidence interval: 0.65 to 2.07 mmHg, p-value = 0.002).AV optima selected using our novel restricted parabola algorithm give a greater improvement in acute hemodynamics than fitting a parabola across all tested AV delays. Such an algorithm may assist the development of automated methods for biventricular pacemaker optimisation.
More Related Videos
06:10Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Related Concept Videos
Mitral Stenosis III: Medical Management
Mitral Regurgitation III: Medical Management
Mechanical Ventilation I: Indication and Settings
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Mitral Valve Prolapse II: Assessment and Management
Aortic Regurgitation III: Medical Management