Phosphorene as a Superior Gas Sensor: Selective Adsorption and Distinct I-V Response

Liangzhi Kou1, Thomas Frauenheim1, Changfeng Chen2

  • 1†Bremen Center for Computational Materials Science, University of Bremen, Am Falturm 1, 28359 Bremen, Germany.

Related Concept Videos

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
1.4K
Adsorption of Gases on Solids01:28

Adsorption of Gases on Solids

Adsorption is a process where molecules, known as the adsorbates, accumulate on a surface, which is referred to as the adsorbent or substrate. Occurring at the solid-gas interface, this phenomenon is crucial in various scientific and industrial contexts. The reverse of adsorption is desorption.Two types of adsorptions exist: physical (physisorption) and chemical (chemisorption). Physisorption involves gas molecules held to the solid's surface by relatively weak intermolecular van der Waals...
219
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
1.3K
Adsorption Isotherms I01:29

Adsorption Isotherms I

Adsorption isotherms are mathematical models that describe how molecules in a gas or liquid phase interact with surfaces. Two of the most common isotherm models are the Langmuir and Freundlich isotherms, which relate to Type I monolayer chemisorption. The Langmuir model is based on four key assumptions:• Adsorption cannot exceed monolayer coverage.• All surface sites are equivalent.• Molecules adsorb only at vacant sites.• There are no interactions between adsorbed...
168
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
2.3K
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
2.0K