Related Experiment Video
Updated: Apr 5, 2026

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
No Benefit of Complex Fractionated Atrial Electrogram Ablation in Addition to Circumferential Pulmonary Vein Ablation
Kelvin C K Wong1, John R Paisey1, Mark Sopher1
1From the Department of Cardiology, Oxford University Hospitals NHS Trust, Oxford, United Kingdom (K.C.K.W., M.J., N.Q., C.R.H., M.R.G., K.R., Y.B., T.R.B.); Department of Cardiology, Royal Bournemouth and Christchurch Hospitals NHS Trust, Dorset, United Kingdom (J.R.P., M.S., R.B.); and Department of Cardiology, Changi General Hospital, Singapore, Singapore (K.C.K.W.).
Background:
The optimal ablation strategy for persistent atrial fibrillation (AF) remains unclear.
Methods And Results:
This multicentre randomized study compared circumferential pulmonary vein ablation+linear ablation (control arm) versus circumferential pulmonary vein ablation+linear ablation+complex fractionated atrial electrogram (CFAE) ablation (CFAE arm) in patients with persistent AF. Circumferential pulmonary vein ablation was performed followed by roof and mitral isthmus ablation, before CFAE ablation in the CFAE arm. Ablation strategy was maintained at the first redo procedure. Sixty-five patients were recruited in each arm. The mean age was 61±10 years, 75% were men, median AF duration was 2 years, 42% had long-lasting persistent AF, 68% had associated cardiovascular disease, mean left atrial dimension was 46±6 mm, and median CHA2DS2-VASc score was 2. Ablation and procedure times were significantly longer in the CFAE arm (70±20 versus 55±17; 201±35 versus 152±45 minutes; P<0.005). After a mean follow-up of 35±5 months, single-procedural success off antiarrhythmic drugs at 12 months (CFAE: 30/65 [46%] versus control: 37/65 [57%]; P=0.29) and multiprocedural success (CFAE: 51/65 [78%] versus control: 52/65 [80%]; P=1.0) were not significantly different. At the first redo procedure, patients in the CFAE arm had a higher incidence of organized atrial tachycardia/flutter (24/33 [73%] versus 11/31 [35%]; P=0.005) and gap-related macro-re-entrant flutter (8/33[24%] versus 1/31[3%]; P=0.03). Early recurrence of atrial arrhythmia was an independent predictor of late recurrence.
Conclusions:
CFAE ablation did not confer incremental benefit when performed in addition to circumferential pulmonary vein ablation and linear ablation. It was associated with a higher incidence of gap-related flutter.
Clinical Trial Registration:
URL: http://www.clinicaltrials.gov. Unique identifier: NCT01711047.
More Related Videos
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...