Related Experiment Video
Updated: Apr 5, 2026

Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
Outcomes of Next-Day Versus Non-next-Day Colonoscopy After an Initial Inadequate Bowel Preparation
Christopher John Murphy1, N Jewel Samadder1, Kristen Cox1
1University of Utah Health Sciences Center, Salt Lake City, UT, USA.
Background:
Inadequate bowel preparation is the most common cause of failed colonoscopy, and repeat failure occurs in more than 20 % of follow-up attempts. Limited data suggest that next-day follow-up may reduce the risk for repeat inadequate preparation.
Objective:
Evaluate differences in prep quality with next-day follow-up after initial inadequate preparation.
Design:
Retrospective study.
Setting:
Academic center.
Patients:
Outpatient screening and surveillance colonoscopies between 7/2002 and 6/2007.
Intervention:
Comparison of next-day versus any other day ("non-next-day") repeat colonoscopy outcomes.
Main Outcome Measurements:
Aronchick scale, polyp and adenoma detection rates.
Results:
Of 20,798 initial colonoscopies, 857 (4.1 %) had inadequate preparation. 460 (54 %) were lost to follow-up. One hundred and fourteen (13 %) had next-day and 283 (33 %) had non-next-day colonoscopy with mean follow-up of 8.8 months. On follow-up examination, 29.8 % of next-day and 23.3 % of non-next-day colonoscopies had inadequate bowel preparation (p = 0.48). The adenoma detection rate for the next-day group improved from 3.5 to 38.6 % on follow-up, compared to 20.5 and 36.8 % in the non-next-day group. There was no significant difference between groups in detection of total adenoma (p = 0.73) or advanced adenomas (p = 0.20) on follow-up examinations.
Limitations:
Retrospective design, differences in baseline colonoscopy characteristics.
Conclusion:
The results confirm the need for repeat examination after a colonoscopy with inadequate bowel prep, as there was substantial increase in adenoma detection on follow-up. There were no differences in outcomes between next-day versus non-next-day colonoscopy. These data support repeating after inadequate colonoscopy within 1 year as convenient for patient and physician.
More Related Videos
06:28E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
04:09The Pocket-Creation Procedure of Endoscopic Submucosal Dissection for Large Rectal Laterally Spreading Tumors
Published on: February 13, 2026
Related Concept Videos
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to: