Toxicological findings in three cases of suicidal asphyxiation with helium
Roelof Oosting1, Rogier van der Hulst1, Leo Peschier2
1Netherlands Forensic Institute (NFI), Department of Forensic Medicine, The Hague, The Netherlands.
Introduction:
Toxicological findings in deaths by asphyxiation due to a pure inert gas like helium are rare. We present three suicide cases of asphyxial death attributed to anoxia caused by inhalation of helium in a plastic bag positioned over the head.
Methods:
In one case, lung tissue, brain tissue and heart blood were obtained during standard autopsy procedures. In two cases, samples were obtained differently: heart blood, femoral blood, brain tissue, lung tissue and/or air from the lungs were directly sealed into headspace vials during autopsy. Air from the lungs was collected using a syringe and transferred into an aluminum gas sampling bag which was heat sealed as soon as possible. Semi-quantitative gas analyses were performed using headspace gas chromatography-thermal conductivity detection (HS-GC/TCD) with a molsieve column capable of separating permanent gasses. Nitrogen was used as carrier gas.
Results:
In the first case no helium was detected in lung tissue, brain tissue and heart blood. In the second case the presence of helium was detected in lung tissue (approximately 5% helium in gaseous phase) but not in femoral blood. In the third case the presence of helium was detected in air from the lungs (0.05%), lung tissue (0.4%), brain tissue (0.1%) and heart blood (0.04%).
Conclusions:
Helium is easily lost if sampling is not performed properly. The presented cases suggest that quick sample collection of various matrices during autopsy is suitable to detect gasses like helium in postmortem cases. Use of HS-GC/TCD enables to detect an inert gas like helium.
More Related Videos
04:56In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells
Published on: October 23, 2018
14:52Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers
Published on: January 13, 2018
Related Concept Videos
Toxidromes: Clinical Features
Inhalational Anesthetics: Overview
Acute Respiratory Failure-III
Acute Respiratory Failure-IV
Pneumothorax-I
Pneumothorax can be even further classified as spontaneous, traumatic, and tension pneumothorax.
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include: