Bolus versus continuous infusion of microbubble contrast agent for liver ultrasound by using an automatic power
Emilio Quaia1, Antonio Giulio Gennari1, Roberta Angileri1
1Department of Radiology, Cattinara Hospital, University of Trieste, Strada di Fiume 447, Trieste, Italy, 34149.
Purpose:
To evaluate the feasibility of using continuous infusion, in comparison with bolus injection, of a sulfur hexafluoride-microbubble contrast agent to prolong the duration of hepatic parenchymal enhancement in humans during sonographic examination.
Methods:
This pilot study was approved by our institution's ethics committee. Ten patients (5 men and 5 women; mean age ± SD, 65 ± 10 years) each received two injections: a bolus injection (2 ml/s) and then continuous infusion (0.5 ml/min) of the contrast agent by using an automatic injector. Acquired cine clips were transferred to a personal computer, and the video intensity was quantified by dedicated software.
Results:
From the time of the first microbubble visualization in the scanning plane, maximal enhancement was reached in 6.3 ± 0.94 seconds after bolus injection and in 13.9 ± 1.44 seconds during continuous infusion (p = 0.002, Wilcoxon's test for paired data). Compared with bolus injection, continuous infusion prolonged the duration of contrast enhancement (4.3 minutes ± 42 seconds versus 7.3 minutes ± 40 seconds; p = 0.002), although no statistically significant difference in maximal enhancement was observed (45 ± 18% for bolus injection and 39 ± 6% for continuous infusion; p = 0.62).
Conclusions:
Continuous infusion of sulfur hexafluoride-filled microbubbles via an automatic power injector prolongs hepatic contrast enhancement without significantly modifying the maximal enhancement over that at baseline. These data, coming from a pilot study, can be used to design a larger study with adequate statistical power.
More Related Videos
06:20Contrast-Enhanced Subharmonic Aided Pressure Estimation SHAPE Using Ultrasound Imaging with a Focus on Identifying Portal Hypertension
Published on: December 5, 2020
08:02A High-Throughput Image-Guided Stereotactic Neuronavigation and Focused Ultrasound System for Blood-Brain Barrier Opening in Rodents
Published on: July 16, 2020
Related Concept Videos
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies III: Computed Tomography
Imaging Studies VII: Vascular Imaging