Tactile Vibrating Toolkit and Driving Simulation Platform for Driving-Related Research
Published on: December 18, 2020
Sürücü index and others
Hüseyin Sürücü1, Corç Baytaroğlu1, Faik Alper Aksoy2
1Private Avcılar Hospital, Cardiology Department, İstanbul, Turkey.
The Sürücü index is a more reliable and usable measure for assessing combined systolic and diastolic heart function compared to Vp and Tei indices. It is less affected by preload and calculated from a single cardiac cycle.
Area of Science:
- Cardiology
- Echocardiography
- Cardiac Physiology
Background:
- Assessing combined systolic and diastolic cardiac function is crucial for diagnosing heart conditions.
- Existing echocardiographic parameters have limitations in accurately evaluating both functions simultaneously.
Purpose of the Study:
- To evaluate the correlation between echocardiographic parameters assessing combined systolic and diastolic function.
- To compare the usability of the Sürücü index against other established indices like Vp and Tei.
Main Methods:
- Patients were categorized into control (Vp > 50 cm/s) and dysfunction (Vp ≤ 50 cm/s) groups.
- Echocardiographic parameters, including Vp, Tei index, and Sürücü index, were measured and compared between groups.
Main Results:
- Patients with combined systolic and diastolic dysfunction (Vp ≤ 50 cm/s) exhibited a higher Tei index and a lower Sürücü index.
- A significant negative correlation was observed between the Tei and Sürücü indices, indicating Tei increases as Sürücü decreases.
Conclusions:
- The Vp index is primarily influenced by diastolic parameters, while the Tei index is affected by preload and requires two cardiac cycles.
- The Sürücü index demonstrates greater usability and reliability due to its independence from preload variables, single-cycle calculation, and assessment of both systolic and diastolic function.
More Related Videos
11:12Driving Simulation in the Clinic: Testing Visual Exploratory Behavior in Daily Life Activities in Patients with Visual Field Defects
Published on: September 18, 2012
09:35Measurement of the Hand Transmitted Vibration of the Human Hand Arm System During Operation of a Hand Tractor
Published on: June 16, 2021
Related Concept Videos
Internal Combustion Engine
Therapeutic Index
Indicators
Design Example: Automobile Ignition System
One can generate a large voltage using a car battery of 12 volts with the help of inductors. Inductors are known for opposing...
Accelerators
The effectiveness of calcium chloride can...
Motor Units
Motor units come in different sizes, with smaller units...