Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

14.8K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
14.8K
Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

12.2K
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
12.2K
Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

15.2K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
15.2K
Three-Dimensional Microscopy in Microbiology01:28

Three-Dimensional Microscopy in Microbiology

1.0K
Three-dimensional imaging techniques are essential in cell biology, allowing researchers to visualize intricate cellular structures with high resolution. Two prominent methods, Differential Interference Contrast Microscopy (DIC) and Confocal Scanning Laser Microscopy (CSLM), provide distinct advantages for imaging live and thick specimens, respectively.Differential Interference Contrast MicroscopyDIC microscopy enhances contrast in transparent, unstained samples by converting phase...
1.0K
Reconstruction of Signal using Interpolation01:10

Reconstruction of Signal using Interpolation

860
Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next...
860

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Compact extended-DOF microscope through electrowetting lens.

Optics express·2025
Same author

Management of the axial modulation of the illumination pattern in structured illumination microscopy using an extended illumination source.

Optics express·2023
Same author

Focus Issue Introduction: 3D Image Acquisition and Display: Technology, Perception and Applications.

Optics express·2023
Same author

Resolution limit in opto-digital systems revisited.

Optics express·2023
Same author

Machine Learning-Based View Synthesis in Fourier Lightfield Microscopy.

Sensors (Basel, Switzerland)·2022
Same author

Fourier lightfield microscopy: a practical design guide.

Applied optics·2022

Related Experiment Video

Updated: Apr 5, 2026

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
06:25

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

Published on: February 12, 2014

8.9K

Resolution enhancement in integral microscopy by physical interpolation.

Anabel Llavador1, Emilio Sánchez-Ortiga1, Juan Carlos Barreiro1

  • 13D Imaging and Display Laboratory, Department of Optics, University of Valencia, E-46100 Burjassot, Spain.

Biomedical Optics Express
|August 27, 2015
PubMed
Summary
This summary is machine-generated.

This study introduces a double-shot integral microscopy technique to enhance 2D spatial resolution by √2. This method overcomes the resolution limitations of single-shot integral imaging for biological specimen analysis.

Keywords:
(100.6890) Three-dimensional image processing(110.6880) Three-dimensional image acquisition(120.2040) Displays(180.6900) Three-dimensional microscopy

More Related Videos

Digital Inline Holographic Microscopy DIHM of Weakly-scattering Subjects
10:16

Digital Inline Holographic Microscopy DIHM of Weakly-scattering Subjects

Published on: February 8, 2014

12.7K
Highly Resolved Intravital Striped-illumination Microscopy of Germinal Centers
10:07

Highly Resolved Intravital Striped-illumination Microscopy of Germinal Centers

Published on: April 9, 2014

10.7K

Related Experiment Videos

Last Updated: Apr 5, 2026

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
06:25

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

Published on: February 12, 2014

8.9K
Digital Inline Holographic Microscopy DIHM of Weakly-scattering Subjects
10:16

Digital Inline Holographic Microscopy DIHM of Weakly-scattering Subjects

Published on: February 8, 2014

12.7K
Highly Resolved Intravital Striped-illumination Microscopy of Germinal Centers
10:07

Highly Resolved Intravital Striped-illumination Microscopy of Germinal Centers

Published on: April 9, 2014

10.7K

Area of Science:

  • Optics and Photonics
  • Microscopy Techniques
  • Computational Imaging

Background:

  • Integral imaging captures depth information from single shots.
  • Integral microscopy enables refocusing but suffers from reduced spatial resolution.
  • High spatial resolution is critical for detailed biological studies.

Purpose of the Study:

  • To develop a technique for enhancing the 2D spatial resolution in integral microscopy.
  • To overcome the inherent spatial resolution limitations of single-shot integral imaging.
  • To demonstrate the applicability of the enhanced resolution technique to biological specimens.

Main Methods:

  • A double-shot approach using a rotating glass plate was employed.
  • The rotating glass plate shifts microimages on the sensor plane.
  • The technique was experimentally validated for resolution enhancement.

Main Results:

  • A spatial resolution increase by a factor of √2 was achieved in computed depth images.
  • The method effectively enhances the 2D spatial resolution of integral microscopy.
  • The technique's benefit was demonstrated on biological specimens.

Conclusions:

  • The proposed double-shot integral microscopy technique significantly improves spatial resolution.
  • This advancement overcomes a key limitation of integral imaging for microscopic applications.
  • The technique offers a valuable tool for high-resolution analysis of biological samples.