Neurologic Complications of Extracorporeal Membrane Oxygenation

Deena M Nasr1, Alejandro A Rabinstein2

  • 1Department of Neurology, Mayo Clinic, Rochester, MN, USA. nasr.deena@mayo.edu.

Abstract

Related Concept Videos

Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications01:25

Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications

Peritoneal dialysis (PD) is a medical process that removes waste products and excess fluid from the body using the peritoneal membrane as a natural filter.Peritoneal Dialysis MethodsSeveral methods can be used for peritoneal dialysis, including Acute Intermittent Peritoneal Dialysis, Continuous Ambulatory Peritoneal Dialysis, and Automated Peritoneal Dialysis, also known as Continuous Cyclic Peritoneal Dialysis.Acute Intermittent Peritoneal Dialysis (AIPD) is used for patients with uremic...
1.7K
Acute Respiratory Failure-III01:30

Acute Respiratory Failure-III

Hypercapnic respiratory failure, also known as Type 2 or ventilatory respiratory failure, is a severe condition characterized by the body's inability to effectively remove carbon dioxide (CO2) from the bloodstream. It leads to an arterial CO2 pressure (PaCO2) exceeding 45 mmHg and a blood pH above 7.35. This situation indicates that the body's ventilatory demand, or the ventilation needed to maintain normal PaCO2 levels, surpasses its supply or the maximum gas flow achievable without...
1.2K
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
1.8K
Acute Respiratory Failure-II01:21

Acute Respiratory Failure-II

Type I Respiratory Failure, or hypoxemic respiratory failure, occurs when the partial pressure of oxygen (PaO2) in arterial blood falls below 60 mmHg while breathing room air without a corresponding increase in arterial carbon dioxide levels (PaCO2). This condition highlights a significant impairment in the lungs' capacity to oxygenate the blood.
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
1.5K
Mechanical Ventilation II: Invasive Ventilation01:23

Mechanical Ventilation II: Invasive Ventilation

Ventilators are essential medical equipment used to aid patients with respiratory difficulties. Their primary function is to assist or replace spontaneous breathing by providing mechanical ventilation. There are two general classes of mechanical ventilators: negative-pressure and positive-pressure ventilators.
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
1.1K
Mechanical Ventilation III: Noninvasive Ventilation01:23

Mechanical Ventilation III: Noninvasive Ventilation

Noninvasive positive-pressure ventilation (NIPPV), continuous positive airway pressure (CPAP), and bilevel positive airway pressure (BiPAP) are essential methods in respiratory care. These ventilation techniques offer unique benefits for patients with various respiratory conditions, providing adequate support without requiring intubation. Let's explore how each method is crucial in improving patient outcomes and enhancing respiratory therapy.
Noninvasive Positive-Pressure Ventilation...
844