An anthracene-appended 2:3 copillar[5]arene: synthesis, computational studies, and application in highly selective
Peifa Wei1, Debing Li, Bingbing Shi
1State Key Laboratory of Chemical Engineering, Department of Chemistry, Zhejiang University, Hangzhou 310027, P. R. China. fhuang@zju.edu.cn.
Abstract:
Herein an anthracene-appended 2:3 copillar[5]arene was prepared by the CuAAC method, which was further used as a Fe(3+)-selective fluorescent chemosensor over a wide range of metal ions.
Related Concept Videos
Photoluminescence: Applications
1.3K
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
1.3K
Variables Affecting Phosphorescence and Fluorescence
2.4K
Fluorescence and phosphorescence are essential phenomena in fields like analytical chemistry, biological imaging, and materials science, where they detect molecular properties and visualize cellular structures. Understanding the variables that influence these luminescent behaviors is crucial for maximizing accuracy and efficiency in their applications. These variables can broadly be grouped into chemical structure, solvent properties, and external conditions, each playing a distinct role in...
2.4K
Atomic Fluorescence Spectroscopy
1.1K
Atomic fluorescence spectroscopy (AFS) is an analytical technique that involves the electronic transitions of atoms in a flame, furnace, or plasma being excited by electromagnetic (EM) radiation. When these atoms absorb energy, they become excited and subsequently release energy as they return to their original state. This emitted light, or "fluorescence," is observed at a right angle to the incident beam. Both absorption and emission processes transpire at distinct wavelengths, which...
1.1K
Fluorescence and Phosphorescence: Instrumentation
2.0K
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
2.0K
FISH - Fluorescent In-situ Hybridization
26.6K
Fluorescence in situ hybridization, or FISH, was developed in the early 1980s and has quickly become one of the most widely used techniques in cytogenetics. Labeled probes are used to bind complementary DNA or RNA sequences on a chromosome or in a region within a cell. Earlier, the probes could only be obtained by cloning or reverse transcription of a DNA template. Currently, the probe oligonucleotides can be synthesized synthetically. Additionally, with the advancement of optical techniques,...
26.6K
Super-resolution Fluorescence Microscopy
14.8K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
14.8K


