Related Experiment Videos
Arterial compliance in uraemia
S Marchais1, A Guérin, M Safar
1Hôpital Manhes, Fleury Merogis, France.
Aortic and brachial pulse wave velocity were measured in 26 haemodialysis patients in order to assess the effect of uraemic waste-product retention on arterial compliance. Dialysis with a 'low-calcium' dialysate (1.50 mmol/l) did not change the pulse wave velocity, but dialysis with a 'high-calcium' dialysate (1.75 mmol/l) induced a significant increase in both aortic and brachial pulse wave velocity. The results indicate that (1) waste-product retention is not responsible for the increased arterial pulse wave velocity observed in uraemic patients and (2) the increase in serum ionized calcium decreases arterial compliance.
Aortic and brachial pulse wave velocity were measured in 26 haemodialysis patients in order to assess the effect of uraemic waste-product retention on arterial compliance. Dialysis with a 'low-calcium' dialysate (1.50 mmol/l) did not change the pulse wave velocity, but dialysis with a 'high-calcium' dialysate (1.75 mmol/l) induced a significant increase in both aortic and brachial pulse wave velocity. The results indicate that (1) waste-product retention is not responsible for the increased arterial pulse wave velocity observed in uraemic patients and (2) the increase in serum ionized calcium decreases arterial compliance.