Abstract:
In patients with head and neck squamous cell carcinoma and high-risk factors, the combination of whole body FDG-PET and contrast-enhanced chest CT has the highest sensitivity and accuracy when screening for distant metastases. The aim of the present study was to retrospectively validate an earlier developed algorithm for interpreting the combination of screening PET and CT. The test cohort consisted of 47 consecutive HNSCC patients with high-risk factors for distant metastases, who had previously undergone FDG-PET and CT and had a minimum 12 months of follow-up. In 12 (26 %) patients, distant metastases were detected during screening or within 12-month follow-up. In patients with locoregional control during follow-up, the sensitivity and specificity were 55 % (95 % CI 23-83 %) and 97 % (95 % CI 82-99 %), respectively, for chest CT, 55 % (95 % CI 23-83 %) and 100 % (95 % CI 88-100 %), respectively, for PET and 73 % (95 % CI 39-94 %) and 100 % (95 % CI 88-100 %), respectively, for the combination of PET and CT. The proposed algorithm was considered to have been validated. In this algorithm, all FDG-PET positive scans for distant metastases (regardless of interpretation of a solid lung lesion on CT) and CT scans with suspicious pulmonary lesions of less than 5-mm diameter (regardless of FDG-PET findings) are considered positive for distant metastases.
More Related Videos
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
08:55A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...