Related Experiment Video
Updated: Apr 4, 2026

An Inertial Measurement Unit Based Method to Estimate Hip and Knee Joint Kinematics in Team Sport Athletes on the Field
Published on: May 26, 2020
Mobile Sensor Application for Kinematic Detection of the Knees
Tossaphon Jaysrichai1, Areerat Suputtitada2, Watcharapong Khovidhungij3
1Biomedical Engineering Program, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand.
Objective:
To correctly measure the knee joint angle, this study utilized a Qualisys motion capture system and also used it as the reference to assess the validity of the study's Inertial Measurement Unit (IMU) system that consisted of four IMU sensors and the Knee Angle Recorder software. The validity was evaluated by the root mean square (RMS) of different angles and the intraclass correlation coefficient (ICC) values between the Qualisys system and the IMU system.
Methods:
Four functional knee movement tests for ten healthy participants were investigated, which were the knee flexion test, the hip and knee flexion test, the forward step test and the leg abduction test, and the walking test.
Results:
The outcomes of the knee flexion test, the hip and knee flexion test, the forward step test, and the walking test showed that the RMS of different angles were less than 6°. The ICC values were in the range of 0.84 to 0.99. However, the leg abduction test showed a poor correlation in the measurement of the knee abduction-adduction movement.
Conclusion:
The IMU system used in this study is a new good method to measure the knee flexion-extension movement.