Related Experiment Video
Updated: Apr 4, 2026

Guidelines for Elective Pediatric Fiberoptic Intubation
Published on: January 17, 2011
[High flow nasal cannula in infants: Experience in a critical patient unit]
Adriana Wegner A1, Pamela Cespedes F1, María Loreto Godoy M1
1Pediatra Intensivista, Unidad de Paciente Crítico Pediátrico (UPCP), Complejo Asistencial Dr. Sotero del Río, Santiago, Chile.
Introduction:
The high flow nasal cannula (HFNC) is a method of respiratory support that is increasingly being used in paediatrics due to its results and safety.
Objective:
To determine the efficacy of HFNC, as well as to evaluate the factors related to its failure and complications associated with its use in infants.
Patients And Method:
An analysis was performed on the demographic, clinical, blood gas, and radiological data, as well as the complications of patients connected to a HFNC in a critical care unit between June 2012 and September 2014. A comparison was made between the patients who failed and those who responded to HFNC. A failure was considered as the need for further respiratory support during the first 48hours of connection. The Kolmogorov Smirnov, Mann-Whitney U, chi squared and the Exact Fisher test were used, as well as correlations and a binary logistic regression model for P≤.05.
Results:
The study included 109 patients, with a median age and weight: 1 month (0.2-20 months) and 3.7kg (2-10kg); 95 percentile: 3.7 months and 5.7kg, respectively. The most frequent diagnosis and radiological pattern was bronchiolitis (53.2%) and interstitial infiltration (56%). Around 70.6% responded. There was a significant difference between failure and response in the diagnosis (P=.013), radiography (P=018), connection context (P<.0001), pCO2 (median 40.7mmHg [15.4-67 mmHg] versus 47.3mmHg [28.6-71.3mmHg], P=.004) and hours on HFNC (median 60.75hrs [5-621.5 hrs] versus 10.5hrs [1-29 hrs], P<.0001). The OR of the PCO2 ≥ 55mmHg for failure was 2.97 (95% CI; 1.08-8.17; P=.035). No patient died and no complications were recorded.
Conclusion:
The percentage success observed was similar to that published. In this sample, the failure of HFNC was only associated with an initial pCO2 ≥ 55mmHg. On there being no complications reported as regards it use, it is considered safe, although a randomised, controlled, multicentre study is required to compare and contrast these results.
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Suctioning the Nasopharyngeal Airway
Equipment Required
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...

