Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

5.3K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
5.3K
Instrument Calibration01:12

Instrument Calibration

1.3K
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
1.3K
Glassware Calibration01:11

Glassware Calibration

2.0K
Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
2.0K
Calibration Curves: Correlation Coefficient01:10

Calibration Curves: Correlation Coefficient

5.7K
In a linear calibration curve, there is a value called the calibration coefficient, denoted by 'r,' which measures the strength and the direction of association between two variables. The correlation coefficient value ranges from −1 to +1. A value of +1 indicates a perfect positive linear correlation, −1 denotes a perfect negative correlation, and 0 implies no correlation between the two variables. A positive correlation value establishes that as one variable increases, the...
5.7K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A clinical evaluation of amlexanox oral adhesive pellicles in the treatment of recurrent aphthous stomatitis and comparison with amlexanox oral tablets: a randomized, placebo controlled, blinded, multicenter clinical trial.

Trials·2009
Same author

Long-term assessment of bladder and bowel dysfunction after radical hysterectomy.

Gynecologic oncology·2009
Same author

Oxidative stress contributes to silica nanoparticle-induced cytotoxicity in human embryonic kidney cells.

Toxicology in vitro : an international journal published in association with BIBRA·2009
Same author

A rapid and simple method for identifying Mycobacterium tuberculosis W-Beijing strains based on detection of a unique mutation in Rv0927c by PCR-SSCP.

Microbes and infection·2009
Same author

CO oxidation over AuPd(100) from ultrahigh vacuum to near-atmospheric pressures: the critical role of contiguous Pd atoms.

Journal of the American Chemical Society·2009
Same author

Daunorubicin-loaded magnetic nanoparticles of Fe(3)O(4) greatly enhance the responses of multidrug-resistant K562 leukemic cells in a nude mouse xenograft model to chemotherapy.

Zhongguo shi yan xue ye xue za zhi·2009
Same journal

Long-term stabilization of intensity-difference squeezing from four-wave mixing in rubidium vapor.

Optics express·2026
Same journal

Robust 3D topography measurement of large-range high-aspect-ratio structures based on dual-domain statistical filtering in SD-OCT.

Optics express·2026
Same journal

Broadband transmissive terahertz metasurface for simultaneous quad-mode OAM multiplexing.

Optics express·2026
Same journal

Leveraging two-dimensional materials for high-sensitivity optical sensors: quasi-bound states in the continuum within hybrid metasurfaces.

Optics express·2026
Same journal

Resolution investigation for dual-spherical-wave optical scanning holographic microscopy: methods and performance.

Optics express·2026
Same journal

Robustness of parallel subnetwork-filtered diffractive deep neural networks.

Optics express·2026
See all related articles

Related Experiment Video

Updated: Apr 3, 2026

Robotized Testing of Camera Positions to Determine Ideal Configuration for Stereo 3D Visualization of Open-Heart Surgery
05:12

Robotized Testing of Camera Positions to Determine Ideal Configuration for Stereo 3D Visualization of Open-Heart Surgery

Published on: August 12, 2021

2.6K

Iterative optimization calibration method for stereo deflectometry.

Hongyu Ren, Feng Gao, Xiangqian Jiang

    Optics Express
    |September 15, 2015
    PubMed
    Summary
    This summary is machine-generated.

    This study presents an accurate system calibration method for stereo deflectometry using an iterative optimization algorithm. The technique minimizes reprojection errors, enhancing overall 3D reconstruction accuracy.

    More Related Videos

    Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration
    07:03

    Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration

    Published on: February 23, 2017

    8.1K
    Stereo-Imaging System DLT Calibration to Capture 3D In Situ Displacements of Stretched Peripheral Nerves
    06:26

    Stereo-Imaging System DLT Calibration to Capture 3D In Situ Displacements of Stretched Peripheral Nerves

    Published on: January 12, 2024

    821

    Related Experiment Videos

    Last Updated: Apr 3, 2026

    Robotized Testing of Camera Positions to Determine Ideal Configuration for Stereo 3D Visualization of Open-Heart Surgery
    05:12

    Robotized Testing of Camera Positions to Determine Ideal Configuration for Stereo 3D Visualization of Open-Heart Surgery

    Published on: August 12, 2021

    2.6K
    Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration
    07:03

    Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration

    Published on: February 23, 2017

    8.1K
    Stereo-Imaging System DLT Calibration to Capture 3D In Situ Displacements of Stretched Peripheral Nerves
    06:26

    Stereo-Imaging System DLT Calibration to Capture 3D In Situ Displacements of Stretched Peripheral Nerves

    Published on: January 12, 2024

    821

    Area of Science:

    • Optics and Photonics
    • Computer Vision
    • Metrology

    Background:

    • Stereo deflectometry systems require precise calibration for accurate 3D surface reconstruction.
    • Existing calibration methods may suffer from limitations in accuracy and parameter optimization.

    Purpose of the Study:

    • To develop an accurate system calibration method for stereo deflectometry.
    • To propose an iterative optimization algorithm to enhance calibration accuracy.
    • To integrate camera parameters and geometric relationships into a unified cost function.

    Main Methods:

    • A novel calibration technique using an optical flat as a reference mirror.
    • Sinusoidal fringe patterns are projected and reflected into two Charge-Coupled Devices (CCDs).
    • An iterative optimization algorithm utilizes the reference mirror's normal vector to minimize reprojection errors.

    Main Results:

    • The proposed method optimizes all system calibration parameters.
    • Significant reduction in root mean square reprojection errors was achieved.
    • Experimental validation confirms improved final 3D reconstruction accuracy.

    Conclusions:

    • The developed system calibration method enhances stereo deflectometry accuracy.
    • The iterative optimization algorithm effectively minimizes errors.
    • This approach provides a robust solution for precise 3D surface metrology.