Related Experiment Video
Updated: Apr 3, 2026

Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
A Radiation Dose Reduction Technology to Improve Patient Safety During Cardiac Catheterization Interventions
John A Bracken1,2, Maria Mauti3, Michael S Kim1
1University of Colorado Denver, Aurora, Colorado.
Objectives:
A novel radiation dose reduction technology was evaluated in a cardiac catheterization laboratory during routine clinical care to determine if it could reduce radiation dose to patients undergoing coronary angiography and percutaneous coronary intervention. These results were compared to patients undergoing similar procedures in a cardiac catheterization laboratory without this technology.
Background:
There is a safety priority in clinical care to reduce X-ray radiation dose to patients in order to lower the risk of deterministic and stochastic effects. Dose reduction technologies must be verified in clinical settings to prove if they reduce X-ray radiation dose and to what extent.
Methods:
Radiation dose data and procedure characteristics of 268 consecutive patients were collected and analyzed from a cardiac catheterization laboratory with dose reduction technology installed (referred to as Lab A, n = 135) and from a cardiac catheterization laboratory without this technology (referred as Lab B, n = 133).
Results:
For diagnostic procedures, the median total dose-area product in Lab A was reduced by 46% (P < 0.0001) compared to Lab B, with no differences in terms of body mass index (P = 0.180), total fluoroscopy times (P = 1), number of acquired images (P = 0.920), and contrast medium (P = 0.660). For interventional procedures, the median total dose-area product in Lab A was reduced by 34% (P = 0.015) compared to Lab B, with no differences in terms of body mass index (P = 0.665), total fluoroscopy times (P = 0.765), number of acquired images (P = 0.923), and contrast medium (P = 0.969).
Conclusions:
This new dose reduction technology significantly reduces X-ray radiation dose without affecting fluoroscopy time, number of images, and contrast medium used during diagnostic and interventional coronary procedures.
More Related Videos
08:30X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Cardiac Catheterization IV: Nursing Management
Cardiac Catheterization I: Pre-Procedure Overview
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Cardiac Catheterization III: Left Heart Catheterization