Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
Performance and Safety of an Integrated Portable Extracorporeal Life Support System for Adults
Abstract:
Extracorporeal membrane oxygenation (ECMO) is indicated when conventional measures fail to support a patient during cardiac or respiratory failure. Due to the complicated nature of ECMO, patients often require transport to a tertiary care center. This study retrospectively compared the performance of the Cardiohelp™ (Maquet) life support system with a previously used ECMO circuit when transporting adult patients on venoarterial ECMO between facilities. Two ECMO circuits were compared for performance: 1) the Cardiohelp™ (Maquet) life support system and 2) the "standard" circuit consisting of a Thoratec CentriMag centrifugal pump, Maquet Quadrox-D oxygenator, and a Terumo CDI-500 in-line blood gas analyzer. After analyzing data from 16 patients (eight patients supported with each ECMO system), no differences in patient demographics, percentage of patients successfully weaned from ECMO, percentage of patients surviving to discharge, duration supported on the initial ECMO system, or total duration of ECMO were noted. No patient deaths were related to circuit failure or circuit disruptions in either group. Analysis of the performance of the ECMO circuits and the resulting patient status showed few significant differences between ECMO groups (Cardiohelp™ vs. standard circuit) and time points (the first 8 hours vs. a 24-hour time point). The statistically significant differences were not concerning in terms of appropriate medical support or patient safety. Of interest, the transmembrane pressure was significantly lower for the Cardiohelp™ module vs. the standard oxygenator during the first 8 hours (20.1 [5.3] vs. 37.1 [7.1] mmHg; p < .001) and at 24 hours (21.3 [3.8] vs. 34.8 [7.9] mmHg; p = .001). The Cardiohelp™ portable life support system provides safe and reliable support for adult patients on ECMO during interhospital patient transport as compared to the standard circuit.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...