Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
Published on: October 2, 2021
Wide-field, full-field optical coherence microscopy for high-axial-resolution phase and amplitude imaging
Abstract:
An original single-objective, full-field optical coherence microscopy system is reported that is capable of imaging both the phase and the amplitude of semi-transparent samples over a field of view of 17.5 mm×17.5 mm with an axial sectioning resolution of 1.5 μm. A special stack acquisition arrangement ensures optimal reachable imaging depth. Several phase-shifting interferometry algorithms for phase measurement with broadband light are compared theoretically and experimentally. Using the phase information, noninvasive depth-resolved topographic images of multilayer samples are produced to characterize each layer by measuring their defects and curvature with a nanometric scale precision. Using the amplitude information, tomographic images with a constant detection sensitivity of ∼80 dB through the entire field of view are obtained and applied to biological specimens.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Atomic Force Microscopy
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...