Related Experiment Video
Updated: Apr 3, 2026

Minimal Invasive Resection of Large Retrosternal Thyroid Goiter
Published on: September 20, 2024
A Tunneled Subcricoid Approach for Anterior Cervical Spine Reoperation: Technical and Safety Results
Ethan A Winkler1, Nathan C Rowland1, John K Yue1
1Department of Neurological Surgery, University of California San Francisco, San Francisco, California, USA.
Objective:
Anterior cervical spine decompression and fusion are common neurosurgical operations. Reoperation of the anterior cervical spine is associated with increased morbidity. The authors describe a novel subcricoid approach to protect the recurrent laryngeal nerve in a cuff of tissue while facilitating surgical access to the anterior cervical spine.
Methods:
Single institution, consecutive case review of 48 patients undergoing reoperation in the anterior cervical region including the level of C5 and below. Univariable and multivariable regression analysis was used to determine predictors of postoperative morbidity.
Results:
No intraoperative complications were reported. Estimated blood loss for the approach was 13.6 ± 3.1 mL. Nine of 48 patients developed immediate postoperative complications, including vocal cord paresis (10.4%), moderate-to-severe dysphagia (10.4%), and neck edema requiring intubation (2.1%). No postoperative hematomas or death occurred. All complications occurred with 4 or more levels of exposure (1-3 disc levels, 0%, vs. ≥ 4 disc levels, 31%). Extension of the exposure to the upper thoracic spine was associated with odds for postoperative complications (adjusted odds ratio, 6.50; 95% confidence interval, 1.14-37.03) and prolonged hospital stay (adjusted increase 4.23 days, P < 0.01).
Conclusion:
The tunneled subcricoid approach is a relatively safe corridor to reapproach the anterior cervical spine at the level of C5 and below. However, caution must be exercised when using this approach to expose 4 or more disc levels and with extension of the exposure to the upper thoracic spine. Future comparative studies are needed to establish patient selection criteria in determining the use of this technique compared with classic approaches.
More Related Videos
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Cardiopulmonary Resuscitation II: ACLS Airway Management
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...