Related Experiment Video
Updated: Apr 3, 2026

Measurement of Spatial Stability in Precision Grip
Published on: June 4, 2020
The Effect of Midcarpal Versus Total Wrist Fusion on the Hand's Load Distribution During Gripping
Marion Mühldorfer-Fodor1, Angela Reger1, Jörg van Schoonhoven1
1Clinic for Hand Surgery, Rhön Klinikum AG, Bad Neustadt/Saale, Germany.
Purpose:
To analyze the total grip force and load distribution of the hand with midcarpal fusion (MCF) and total wrist fusion (TWF).
Methods:
Twelve patients with unilateral TWF and 12 patients with unilateral MCF were assessed at an average 64 months (range, 19-100 months) postoperatively. The total grip force and load distribution of both hands were measured by the Manugraphy system using 3 cylinder sizes. The load applied to 7 anatomical areas of the hand during cylinder grip was analyzed, comparing the operated and the nonsurgical hands.
Results:
For the 100 mm and 150 mm cylinders, a significantly lower total grip force was found in hands operated with either TWF or MCF. For the 200 mm cylinder, there was a significant difference between nonsurgical hands and those with MCF but not between nonsurgical hands and those with TWF. For the 100 mm cylinder, the difference between nonsurgical and operated hands was greater in hands with TWF than those with MCF. For the load distribution of the hand, no differences between the operated and the nonsurgical hand were found for either MCF or TWF.
Conclusions:
MFC and TWF resulted in a reduced cylinder grip force. With respect to the load distribution, neither procedure influenced the relative contribution that each area of the hand produced during cylinder grip.
Type Of Study/Level Of Evidence:
Therapeutic III.
Related Concept Videos
Muscles of the Forearm that Move the Hand and Fingers
Anterior Compartment
The anterior compartment muscles originate from the humerus. They primarily function as flexors and are also known as flexor muscles. They typically insert on the carpals, metacarpals, and phalanges. The superficial layer includes the flexor carpi...
Machines: Problem Solving I
The toggle clamp system is a machine structure consisting of movable, pin-connected multi-force members that form a stabilized system to transmit forces. The...
Normal Strain under Axial Loading
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...