Ankle-Brachial Index, Toe-Brachial Index, and Pulse Volume Recording in Healthy Young Adults
Yoshiko Watanabe1, Hisao Masaki2, Yasuhiro Yunoki2
1First Department of Physiology, Kawasaki Medical School, Kurashiki, Okayama, Japan.
Objective:
To clarify the characteristics of ankle-brachial index (ABI), toe-brachial index (TBI), and pulse volume recording (PVR) of the ankle with brachial-ankle pulse wave velocity (baPWV) in healthy young adults.
Material And Methods:
We analyzed ABI, TBI, baPWV, and PVR in the ankle of healthy adults aged 20 to 25 years (median, 20 years) using an automatic oscillometric device between 2002 and 2013. The ABI, baPWV, and PVR in 1282 legs of 641 subjects (301 men and 340 women) and the TBI in 474 toes of 237 subjects (117 men and 120 women) were evaluated.
Results:
The measured values showed no bilateral differences. ABI and baPWV were higher in men than in women, but TBI was similar in both sexes. ABI <1.0 was observed in 18.1% of the legs in men and in 25.6% in women. TBI <0.7 was observed in 16.2% of the toes in men and 19.1% in women. For ankle PVR, the % mean arterial pressure was higher in women than in men. The upstroke time was <180 ms in most subjects.
Conclusions:
For young people, ABI <1.0 or TBI <0.7 may not always indicate vascular abnormalities. When evaluating circulatory indexes, age and sex should be considered.
Related Concept Videos
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure in the Leg
Preparation:
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: