Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Biasing of FET01:22

Biasing of FET

950
Biasing a Junction Field Effect Transistor (JFET) is crucial for setting operational parameters and ensuring efficient functioning in electronic circuits. JFETs are characterized by using a single carrier type in N-channel or P-channel configurations, where the channel is surrounded by PN junctions. These junctions are central to the device's ability to control current flow.
In an N-channel JFET, the structure consists of N-type material forming the channel on a P-type substrate, with the...
950
Biasing of P-N Junction01:16

Biasing of P-N Junction

2.6K
The operation of a p-n junction diode involves various biasing conditions, including forward bias, reverse bias, and equilibrium.
In equilibrium, no external voltage is applied across the p-n junction. The depletion region is formed at the junction interface due to the diffusion of carriers, which leaves behind charged dopants, acceptors on the p-side, and donors on the n-side. These immobile charges create an electric field that prevents further diffusion of carriers. The related energy band...
2.6K
Biasing of Metal-Semiconductor Junctions01:27

Biasing of Metal-Semiconductor Junctions

840
Biasing metal-semiconductor junctions involves applying a voltage across the junction. Specifically, the metal is connected to a voltage source, while the semiconductor is grounded. This technique is essential for controlling the direction and magnitude of current flow in electronic devices, including diodes, transistors, and photovoltaic cells.
In Schottky junctions, where the semiconductor is n-type, applying a positive voltage to the metal relative to the semiconductor reduces its Fermi...
840
Nuclear Overhauser Enhancement (NOE)01:06

Nuclear Overhauser Enhancement (NOE)

1.6K
Irradiation of a spin-active nucleus causes an increase or decrease in the signal intensity of neighboring nuclei that are not necessarily chemically bonded or involved in J-coupling. This phenomenon, called the nuclear Overhauser enhancement (NOE), results from through-space interactions between the nuclear spins. The NOE effect decreases with increasing internuclear distance and is generally not observed beyond 4 angstroms. In NOE, dipole-dipole interactions between neighboring spin-active...
1.6K
Directionality of Nuclear Transport01:42

Directionality of Nuclear Transport

5.1K
Ras-related nuclear protein or Ran is a small G protein that cycles between its GTP and GDP bound states. Ran specific regulators, a Ran GTPase Activating Protein or RanGAP present in the cytosol and a Ran guanine nucleotide exchange factor or RanGEF present inside the nucleus regulate GTP/GDP exchange. A high concentration of GTP inside the cells, in addition to this asymmetric distribution of  Ran-specific regulators, leads to a higher RanGTP concentration inside the nucleus. This...
5.1K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Dose to medium versus dose to water as an estimator of dose to sensitive skeletal tissue.

Physics in medicine and biology·2010
Same author

Skeletal dosimetry in cone beam computed tomography.

Medical physics·2009
Same author

A "HOWFARLESS" option to increase efficiency of homogeneous phantom calculations with DOSXYZnrc.

Medical physics·2007
Same author

Technical note: overprediction of dose with default PRESTA-I boundary crossing in DOSXYZnrc and BEAMnrc.

Medical physics·2007
Same author

Efficient photon beam dose calculations using DOSXYZnrc with BEAMnrc.

Medical physics·2006
Same author

Influence of ion chamber response on in-air profile measurements in megavoltage photon beams.

Medical physics·2005

Related Experiment Video

Updated: Apr 1, 2026

Sample Preparation and Experimental Design for In Situ Multi-Beam Transmission Electron Microscopy Irradiation Experiments
08:31

Sample Preparation and Experimental Design for In Situ Multi-Beam Transmission Electron Microscopy Irradiation Experiments

Published on: June 27, 2022

2.4K

Increasing efficiency of BEAMnrc-simulated Co-60 beams using directional source biasing.

B R B Walters1

  • 1Ionizing Radiation Standards, National Research Council Canada, Ottawa, Ontario K1A 0R6, Canada.

Medical Physics
|October 3, 2015
PubMed
Summary
This summary is machine-generated.

Directional Source Biasing (DSB) significantly enhances Cobalt-60 (Co-60) beam simulations by improving efficiency by over 1000x. This makes Monte Carlo commissioning and beam quality factor calculations practical for Co-60 radiotherapy.

More Related Videos

X-ray Beam Induced Current Measurements for Multi-Modal X-ray Microscopy of Solar Cells
10:16

X-ray Beam Induced Current Measurements for Multi-Modal X-ray Microscopy of Solar Cells

Published on: August 20, 2019

14.6K
Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
14:11

Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis

Published on: March 29, 2016

27.8K

Related Experiment Videos

Last Updated: Apr 1, 2026

Sample Preparation and Experimental Design for In Situ Multi-Beam Transmission Electron Microscopy Irradiation Experiments
08:31

Sample Preparation and Experimental Design for In Situ Multi-Beam Transmission Electron Microscopy Irradiation Experiments

Published on: June 27, 2022

2.4K
X-ray Beam Induced Current Measurements for Multi-Modal X-ray Microscopy of Solar Cells
10:16

X-ray Beam Induced Current Measurements for Multi-Modal X-ray Microscopy of Solar Cells

Published on: August 20, 2019

14.6K
Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
14:11

Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis

Published on: March 29, 2016

27.8K

Area of Science:

  • Medical Physics
  • Computational Physics
  • Radiotherapy Physics

Background:

  • Simulating Cobalt-60 (Co-60) beams with Monte Carlo methods like BEAMnrc is computationally intensive.
  • Previous methods faced challenges with tracking unproductive photons and simulating secondary particles, limiting practical application.

Purpose of the Study:

  • To implement and evaluate a Directional Source Biasing (DSB) scheme for efficient simulation of Co-60 treatment heads.
  • To overcome the computational limitations of traditional Monte Carlo simulations for Co-60 beams.

Main Methods:

  • The DSB scheme splits photons from the Co-60 source, focusing computational effort on those directed towards the treatment field.
  • Radial symmetry was exploited to further enhance efficiency in specific parts of the simulation.
  • The scheme includes an option for generating contaminant electrons.

Main Results:

  • DSB improved photon fluence calculation efficiency by factors of 1800 (BEAMnrc) and 2800 (beampp).
  • Contaminant electron fluence calculation efficiency increased by factors of 1200 (BEAMnrc) and 1600 (beampp).
  • Dose calculation efficiency in a water phantom improved by approximately 400x, enabling precise beam quality factor calculations.

Conclusions:

  • The DSB technique dramatically increases simulation efficiency for Co-60 beams.
  • This advancement makes Monte Carlo-based commissioning and the calculation of beam quality correction factors feasible for Co-60 radiotherapy units.