Related Experiment Video
Updated: Apr 1, 2026

Synthesis and Calibration of Phosphorescent Nanoprobes for Oxygen Imaging in Biological Systems
Published on: March 3, 2010
Phosphorescent Zinc Probe for Reversible Turn-On Detection with Bathochromically Shifted Emission
Seung Yeon Ryu1, Mijoung Huh1, Youngmin You1
1Department of Chemistry and Nano Science and ‡Division of Chemical Engineering and Materials Science, Ewha Womans University , Seoul 120-750, Korea.
Abstract:
Phosphorescent molecules are attractive complements to fluorescent compounds for bioimaging. Time-gated acquisition of the long-lived phosphorescence signals provides an effective means to eliminate unwanted background noises due to short-lived autofluorescence. We have previously investigated the molecular principles governing modulation of photoinduced electron transfer in phosphorescence zinc probes that were based on biscyclometalated Ir(III) complexes (Woo, H. et al. J. Am. Chem. Soc. 2013, 135, 4771-4787). The studies established that phosphorescence turn-on responses would be attainable for Ir(III) complexes with high triplet-state energies. This sets an upper limit to an emission wavelength, restricting the development of red- or near-IR-phosphorescence turn-on probes. To address this challenge, we designed and synthesized a new phosphorescent probe having an electron-deficient 2-(2-pyridyl)pyrazine diimine ligand tethering a di(2-picolyl)amine (DPA) zinc receptor. This ligand control led to red phosphorescence emission (λ(ems) = 596 nm), with an excited-state reduction potential (E*(red)) retained as high as 1.44 V versus standard calomel electrode (SCE). The E*(red) value was more positive than the ground-state oxidation potential of DPA (1.05 V vs SCE), permitting an occurrence of photoinduced electron transfer at a rate of 2 × 10(7) s(-1). Zinc binding at DPA abolished the electron transfer to produce phosphorescence turn-on signaling. The probe was capable of detecting zinc ions selectively over other competing biological metal ions in aqueous buffer solutions (pH 7.4, 20 mM piperazine-N,N'-bis(2-ethanesulfonic aid)) with the zinc dissociation constant of 109 pM. Finally, bioimaging utility of the probe has been successfully demonstrated by visualizing exogenously supplied zinc ions in live HeLa cells. The research described in this paper demonstrates that judicious ligand control enables retention of turn-on responses in the low-energy phosphorescence region.
More Related Videos
06:08Time-resolved Photophysical Characterization of Triplet-harvesting Organic Compounds at an Oxygen-free Environment Using an iCCD Camera
Published on: December 27, 2018
07:44Synthesis of Wavelength-shifting DNA Hybridization Probes by Using Photostable Cyanine Dyes
Published on: July 6, 2016
Related Concept Videos
Photoluminescence: Applications
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Fluorescence and Phosphorescence: Instrumentation
Photoluminescence: Fluorescence and Phosphorescence
A pair of electrons in a...
Variables Affecting Phosphorescence and Fluorescence