Related Experiment Video
Updated: Apr 1, 2026

The α-test: Rapid Cell-free CD4 Enumeration Using Whole Saliva
Published on: May 16, 2012
Accuracy and Acceptability of Oral Fluid HIV Self-Testing in a General Adult Population in Kenya
Ann E Kurth1, Charles M Cleland2, Nok Chhun2
1New York University College of Nursing, 433 First Avenue, 7th Floor, New York, NY, 10003, USA. akurth@nyu.edu.
Abstract:
We evaluated performance, accuracy, and acceptability parameters of unsupervised oral fluid (OF) HIV self-testing (HIVST) in a general population in western Kenya. In a prospective validation design, we enrolled 240 adults to perform rapid OF HIVST and compared results to staff administered OF and rapid fingerstick tests. All reactive, discrepant, and a proportion of negative results were confirmed with lab ELISA. Twenty participants were video-recorded conducting self-testing. All participants completed a staff administered survey before and after HIVST to assess attitudes towards OF HIVST acceptability. HIV prevalence was 14.6 %. Thirty-six of the 239 HIVSTs were invalid (15.1 %; 95 % CI 11.1-20.1 %), with males twice as likely to have invalid results as females. HIVST sensitivity was 89.7 % (95 % CI 73-98 %) and specificity was 98 % (95 % CI 89-99 %). Although sensitivity was somewhat lower than expected, there is clear interest in, and high acceptability (94 %) of OF HIV self-testing.