Accurate and precise plasma clearance measurement using four 99mTc-DTPA plasma samples over 4 h
Surajith N Wanasundara1, Michal J Wesolowski, Mark C Barnfield
1aDepartment of Medical Imaging, Royal University Hospital, College of Medicine, University of Saskatchewan, Saskatoon, Saskatchewan bDepartment of Radiology, Memorial University of Newfoundland, Nuclear Medicine, The General Hospital, St. John's, Newfoundland and Labrador, Canada cThe Department of Medical Physics and Engineering, St. James's University Hospital, Leeds dNuclear Medicine Department, Sheffield Teaching Hospital NHS Foundation Trust, Sheffield eNuclear Medicine Department, The Royal Free London NHS Foundation Trust, London, UK.
Objectives:
Glomerular filtration rate can be measured as the plasma clearance (CL) of a glomerular filtration rate marker despite body fluid disturbances using numerous, prolonged time samples. We desire a simplified technique without compromised accuracy and precision.
Materials And Methods:
We compared CL values derived from two plasma concentration curve area methods - (a) biexponential fitting [CL (E2)] and (b) Tikhonov adaptively regularized gamma variate fitting [CL (Tk-GV)] - for 4 versus 8 h time samplings from 412 Tc-DTPA studies in 142 patients, mostly paediatric patients, with suspected fluid disturbances.
Results:
CL (Tk-GV) from four samples/4 h and from nine samples/8 h, both accurately and precisely agreed with the standard, which was taken to be nine samples/8 h CL from (noncompartmental) numerical integration [CL (NI)]. The E2 method, four samples/4 h, and nine samples/8 h median CL values significantly overestimated the CL (NI) values by 4.9 and 3.8%, respectively.
Conclusion:
Compared with the standard, CL (E2) from four samples/4 h and from nine samples/8 h proved to be the most inaccurate and imprecise method examined, and can be replaced by better methods for calculating CL. The CL (Tk-GV) can be used to reduce sampling time in half from 8 to 4 h and from nine to four samples for a precise and accurate, yet more easily tolerated and simplified test.
Related Concept Videos
Measurement of Bioavailability: Pharmacokinetic Methods
Clearance Models: Noncompartmental Models
The noncompartmental approach capitalizes on extensive sampling data, correlating the volume of distribution to systemic exposure and the administered dosage. This method enables...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Noncompartmental Analysis: Miscellaneous Pharmacokinetic Parameters
One key aspect of the noncompartmental approach is determining a drug's total clearance. This can be done by dividing the drug dose by the area under the concentration-time curve from zero to infinity. The area under the concentration-time curve represents the drug's...
Drug Elimination: The Concept of Clearance
Drug clearance is not limited to renal excretion but encompasses all organs involved in drug elimination,...
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...


