Related Experiment Video
Updated: Mar 31, 2026

Multispectral Optoacoustic Tomography for Functional Imaging in Vascular Research
Published on: June 8, 2022
High-Throughput Sparsity-Based Inversion Scheme for Optoacoustic Tomography
Abstract:
The concept of sparsity is extensively exploited in the fields of data acquisition and image processing, contributing to better signal-to-noise and spatio-temporal performance of the various imaging methods. In the field of optoacoustic tomography, the image reconstruction problem is often characterized by computationally extensive inversion of very large datasets, for instance when acquiring volumetric multispectral data with high temporal resolution. In this article we seek to accelerate accurate model-based optoacoustic inversions by identifying various sources of sparsity in the forward and inverse models as well as in the single- and multi-frame representation of the projection data. These sources of sparsity are revealed through appropriate transformations in the signal, model and image domains and are subsequently exploited for expediting image reconstruction. The sparsity-based inversion scheme was tested with experimental data, offering reconstruction speed enhancement by a factor of 40 to 700 times as compared with the conventional iterative model-based inversions while preserving similar image quality. The demonstrated results pave the way for achieving real-time performance of model-based reconstruction in multi-dimensional optoacoustic imaging.
More Related Videos
15:18Near Infrared Optical Projection Tomography for Assessments of β-cell Mass Distribution in Diabetes Research
Published on: January 12, 2013
09:56Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time
Published on: November 4, 2014
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...