Related Experiment Video
Updated: Mar 31, 2026

Fabrication and Characterization of a Conformal Skin-like Electronic System for Quantitative, Cutaneous Wound Management
Published on: September 2, 2015
Correlation Between Wound Temperature Obtained With an Infrared Camera and Clinical Wound Bed Score in Venous Leg
Valentina Dini1, Pietro Salvo2, Agata Janowska1
1Department of Dermatology, University of Pisa, Italy;
Introduction:
The measurement of skin and wound bed temperature in chronic wounds may be a useful way to optimize the assessment and diagnosis of chronic wound infection. The aim of this clinical research trial was to correlate the wound bed score, validated by Falanga in 2006, to wound bed and perilesional skin temperature with an easy-to-use, handheld, noninvasive thermometer.
Materials And Methods:
In this study, the authors recruited 18 patients affected by venous insufficiency and lower leg ulcers. A total of 24 chronic wound bed and perilesional skin ulcers were assessed using an infrared camera (FLIR T620 Thermal Imager, FLIR Systems Boston, MA). At the same visit, an operator blinded to the thermal image results made a wound bed score to make a clinical evaluation of the lesion.
Results:
The wound bed temperature range after dressing removal was between 31°C and 35°C, and the perilesional skin temperature range was between 31°C and 34°C. The wound bed score range was between 5-14 (14 patients > 10; 11 patients ≤ 10). The study data showed an increasing relationship between the wound bed score and the wound bed temperature according to several studies that have demonstrated 33°C is the critical temperature level required for normal cellular activity. The correlation between the wound bed score and the perilesional skin temperature is weaker compared to other measurements.
Conclusion:
The results obtained in this preliminary research suggest that this correlation is worth being further investigated with a larger dataset.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Venous Thrombosis IV: Nursing Management
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Varicose Veins II: Diagnostic Studies and Interprofessional Care