Related Experiment Video
Updated: Mar 31, 2026

10:52
Direct Imaging of Laser-driven Ultrafast Molecular Rotation
Published on: February 4, 2017
10.3K
Phase-only synthesis of ultrafast stretched square pulses
Optics Express
|October 20, 2015
Abstract:
We report the generation of square temporal-shape pulses with no loss of spectral bandwidth, using an analytic expression for the spectral phase modulation dependent only on the input spectrum and stretching factor. We demonstrate numerically and experimentally conversion of 40fs pulses into 150 times longer flat top pulses with sharp on and off fronts. Applications in pulse amplification and free electron lasers are considered.
Related Concept Videos
Rectangular and Triangular Pulse Function
2.2K
The unit rectangular pulse function is mathematically represented by a rectangular function centered at the origin with a height of one unit. This function is defined by two parameters: T, which specifies the center location of the pulse along the time axis, and τ, which determines the pulse duration.
For example, consider a rectangular pulse with a 5V amplitude, a 3-second duration, and centered at t=2 seconds. This pulse can be expressed using the rectangular function, written as,
For example, consider a rectangular pulse with a 5V amplitude, a 3-second duration, and centered at t=2 seconds. This pulse can be expressed using the rectangular function, written as,
2.2K
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
2.0K
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
2.0K
IR Frequency Region: X–H Stretching
1.8K
In IR spectroscopy, signals produced by the X−H bonds (such as C−H, O−H, or N−H) can be observed in the frequency range of 2700–4000 cm–1. The C−H stretching vibration forms sharp bands in the region 2850–3000 cm–1. The presence of the O−H stretching vibration leads to the forming of an absorption band in the frequency range 3650–3200 cm−1. At the same time, N−H stretching can be confirmed by absorption bands in...
1.8K
Double Resonance Techniques: Overview
853
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Spin decoupling is usually achieved by...
853
Upsampling
703
Managing signal sampling rates is essential in digital signal processing to maintain signal integrity. A decimated signal, characterized by a reduced frequency range due to its lower sampling rate, can be upsampled by inserting zeros between each sample. This upsampling process expands the original spectrum and introduces repeated spectral replicas at intervals dictated by the new Nyquist frequency. To refine this zero-inserted sequence, it is passed through a lowpass filter with a cutoff...
703

