Purpose:
To describe the SpO2 in wakefulness, sleep and during the apnea-hypopnea in adults living in Bogotá, located at 2640 m above sea level.
Methods:
Descriptive observational study in adults referred for polysomnogram (PSG). A normal Apnea hypopnea index (AHI) was defined as ≤5 and obstructive sleep apnea (OSA) was classified as mild (AHI 5-15), moderate (AHI 15-30), and severe (AHI >30). T-test or ANOVA test for SpO2 differences between groups was used.
Results:
1799 patients, 33% women. 222 (12.8%) did not have OSA (normal IAH), 268 (14.9%) mild OSA, 315 (17.5%) moderate ,and 993 (55.2%) severe. In all cases a low SpO2 (SpO2<90%) was found. The SpO2 was lower when the AHI was higher, in wakefulness, in non-REM and in REM (p<0.001). For all grades of severity, SpO2 decreased significantly from wakefulness to non-REM sleep and to REM sleep (p<0.001). Patients with severe OSA had higher desaturation during wakefulness (85.2±6.6%), non-REM sleep (83.1±7.7%), REM sleep (78.8±10.2), and during events (75.1±9.1%).
Conclusions:
Patients with OSA at 2640 m have nocturnal desaturation lower than 88%, which decreases with higher severity of OSA. The clinical impact of sleep disorders at this point may be greater than at sea level and should be studied.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Sleep Apnea
The condition is more prevalent among...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Factors Affecting Respiration
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Hyperpnea and Hyperventilation