Reversible Electrochemical Sensor for Detection of High-Charge Density Polyanion Contaminants in Heparin
Jacob Lester1, Timothy Chandler1, Kebede L Gemene1
1Department of Chemistry, Northern Kentucky University , Nunn Drive, Highland Heights, Kentucky 41099, United States.
Abstract:
We present a simple, rapid, and inexpensive electrochemical sensor based on a reversible pulsed chronopotentiometric polyanion-selective membrane electrode for the detection and quantification of oversulfated chondroitin sulfate (OSCS) and other high charge-density polyanions that could potentially be used to adulterate heparin. The membrane is free of ion exchanger and is formulated with plasticized poly(vinyl chloride) (PVC) and an inert lipophilic salt, tridodecylmethylammonium-dinonylnaphthaline sulfonate (TDMA-DNNS). The neutral salt is used to reduce membrane resistance and to ensure reversibility of the sensor. More importantly, TDMA(+) is used as the recognition element for the polyanions. Here an anodic galvanostatic current pulse is applied across the membrane to cause the extraction of the polyanions from the sample into the membrane and potential is measured at the sample-membrane interface. The measured electromotive force (emf) is proportional to the concentration and the charge density of the polyanions. High charge-density polyanion contaminants and impurities in heparin can be detected using this method since the overall equilibrium potential response of polyions increases with increasing charge density of the polyions. Here, first the potential response of pure heparin is measured at a saturation concentration, the concentration beyond which further addition of heparin does not produce a change in potential response. Then the potential response of heparin tainted with different quantities of the high charge-density contaminant is measured at a fixed total polyion concentration (heparin concentration + contaminant concentration). The latter gives a greater negative potential response due to the presence of the high charge-density contaminant. The increase in the negative potential response can be used for detection and quantification of high charge-density contaminants in heparin. We demonstrate here that 0.3% (w/w) OSCS as well as 0.1% (w/w) dextran sulfate can be detected in heparin at 20-mg/mL total polyion concentration. It has also been shown that 1% (w/w) of dextran sulfate can readily be detected in heparin at only 2-mg/mL total polyanion concentration with a linear response (R(2) = 0.994).
More Related Videos
13:15Fabrication of Electrochemical-DNA Biosensors for the Reagentless Detection of Nucleic Acids, Proteins and Small Molecules
Published on: June 1, 2011
09:33Phthalic Acid Ester-Binding DNA Aptamer Selection, Characterization, and Application to an Electrochemical Aptasensor
Published on: March 21, 2018
Related Concept Videos
Ion-Exchange Chromatography
Potentiometry: Membrane Electrodes
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Ion Exchange
Capillary Electrophoresis: Instrumentation
Electrodeposition
Electrodeposition can...