Electroretinography (ERG) helps diagnose Usher syndrome in children with sensorineural hearing loss (SNHL). Key indicators include cochlear implants, retinal dystrophy symptoms, and profound hearing loss.
Area of Science:
- Ophthalmology
- Genetics
- Pediatrics
Background:
- National Deaf Children's Society guidelines recommend ophthalmological screening for children with sensorineural hearing loss (SNHL).
- Electroretinography (ERG) is suggested to screen for Usher syndrome in children with SNHL.
- This study investigates ERG findings in children with SNHL to identify Usher syndrome risk factors.
Purpose of the Study:
- To determine the prevalence of abnormal ERG findings in children with SNHL.
- To identify risk factors associated with Usher syndrome diagnosis in this cohort.
- To evaluate the utility of ERG in diagnosing Usher syndrome.
Main Methods:
- Retrospective review of medical records of children (<18 years) with SNHL referred for ERG.
- Inclusion criteria: referral by audiological medicine consultant with possible Usher syndrome as primary indication.
- Data collected from January 2009 to December 2011 at Moorfields Eye Hospital, London.
Main Results:
- 15% (13/84) of cases showed ERG findings consistent with Usher syndrome (rod-cone dysfunction).
- Two patients with retinal pigmentary changes and normal ERGs were diagnosed with rubella retinopathy.
- Predictive factors for Usher syndrome included cochlear implants, retinal dystrophy signs/symptoms, and profound hearing loss; age, sex, and bilateral hearing loss were not predictive.
Conclusions:
- ERG is a valuable diagnostic tool for children with SNHL.
- ERG screening is recommended for children with SNHL who have cochlear implants or signs/symptoms of retinal dystrophy.
- A targeted ERG approach may offer cost savings.
Background:
The guidelines of the National Deaf Children's Society recommend that children with sensorineural hearing loss (SNHL) be routinely screened for ophthalmological problems and suggest electroretinography (ERG) to exclude Usher syndrome. The present study reports the nature and prevalence of abnormal ERG findings in a cohort of children with SNHL undergoing ERG with the aim of identifying risk factors for the diagnosis of Usher syndrome.
Methods:
The medical records of children (<18 years of age) with SNHL referred for ERG at Moorfields Eye Hospital, London, between January 2009 and December 2011 were retrospectively reviewed. Patients were included if they had been referred with SNHL by an audiological medicine consultant and the primary indication for electrodiagnostic testing was possible Usher syndrome.
Results:
A total of 84 cases met inclusion criteria of which 13 (15%) had ERG findings showing rod-cone dysfunction consistent with a diagnosis of Usher syndrome. Two patients with retinal pigmentary changes had normal ERGs and were diagnosed with rubella retinopathy based on the clinical findings. Risk factor analysis showed that age of ≥8 years at the time of ERG, sex, and bilateral hearing loss were not predictive of a diagnosis of Usher syndrome. However, the presence of or referral for cochlear implants, having relevant symptoms and/or clinical signs consistent with a retinal dystrophy, and profound hearing loss were all highly predictive.
Conclusions:
ERG is a useful diagnostic tool in children with SNHL and should be performed in children with SNHL who have cochlear implants and/or have signs or symptoms of retinal dystrophy. A focused approach could have potential cost-saving benefit.
More Related Videos
06:34Using the Electroretinogram to Assess Function in the Rodent Retina and the Protective Effects of Remote Limb Ischemic Preconditioning
Published on: June 9, 2015
10:30Simultaneous Recording of Electroretinography and Visual Evoked Potentials in Anesthetized Rats
Published on: July 1, 2016