Direct electrochemical analysis in complex samples using ITO electrodes modified with permselective membranes

Fei Yan1, Wenjing Zheng, Lina Yao

  • 1Institute of Microanalytical Systems, Department of Chemistry & Center for Chemistry of High-Performance and Novel Materials, Zhejiang University, Hangzhou 310058, China. subin@zju.edu.cn.

Chemical Communications (Cambridge, England)
|October 23, 2015
PubMed

Related Concept Videos

Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
2.9K
Capillary Electrophoresis: Applications01:30

Capillary Electrophoresis: Applications

Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
1.8K
Interfacial Electrochemical Methods: Overview01:06

Interfacial Electrochemical Methods: Overview

Interfacial electrochemical methods focus on the phenomena occurring at the boundary between an electrode and a solution, as opposed to bulk methods that concentrate on the solution's overall properties. These interfacial methods are classified as either static or dynamic based on the presence of a nonzero current in the electrochemical cell and the consistency of analyte concentrations. Static methods, such as potentiometry, measure the cell's potential without any significant current...
1.1K
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
2.3K
Dialysis01:15

Dialysis

Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...
2.2K
Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
1.7K