Related Experiment Video
Updated: Mar 31, 2026

Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as a Contrast Agent
Published on: June 5, 2019
Ventilation heterogeneity is increased in patients with chronic heart failure
Kirk Kee1, Christopher Stuart-Andrews2, Kris Nilsen3
1Department of Medicine, Central Clinical School, Monash University, Melbourne, Australia Department of Allergy, Immunology and Respiratory Medicine, Melbourne, Australia k.kee@alfred.org.au.
Abstract:
In the healthy lung, ventilation is distributed heterogeneously due to factors such as anatomical asymmetry and gravity. This ventilation heterogeneity increases pathologically in conditions such as asthma, chronic obstructive lung disease, and cystic fibrosis. In chronic heart failure, lung biopsy demonstrates evidence of peripheral lung fibrosis and small airways narrowing and distortion. We hypothesized that this would lead to increased ventilation heterogeneity. Furthermore, we proposed that rostral fluid shifts when seated patients lie supine would further increase ventilation heterogeneity. We recruited 30 ambulatory chronic heart failure patients (57 ± 10 years, 83% male, left ventricular ejection fraction 31 ± 12%) as well as 10 healthy controls (51 ± 13 years, 90% male). Heart failure patients were clinically euvolemic. Subjects underwent measurement of ventilation heterogeneity using the multiple-breath nitrogen washout technique in the seated position, followed by repeat measurements after 5 and 45 min in the supine position. Ventilation heterogeneity was calculated using the lung clearance index (LCI), Sacin and Scond which represent overall, acinar, and small conducting airway function, respectively. Lung clearance index (9.6 ± 1.2 vs. 8.6 ± 1.4 lung turnovers, P = 0.034) and Scond (0.029 ± 0.014 vs. 0.006 ± 0.016/L, P = 0.007) were higher in the heart failure patients. There was no difference in Sacin (0.197 ± 0.171 vs. 0.125 ± 0.081/L, P = 0.214). Measures of ventilation heterogeneity did not change in the supine position. This study confirms the presence of peripheral airway pathology in patients with chronic heart failure. This leads to subtle but detectable functional abnormalities which do not change after 45 min in the supine position.
More Related Videos
05:56Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: