Related Experiment Video
Updated: Mar 31, 2026

Microfluidic Flow Chambers Using Reconstituted Blood to Model Hemostasis and Platelet Transfusion In Vitro
Published on: March 19, 2016
Platelet function in reconstituted whole blood variants: An observational study over 5 days of storage time
Martin Ponschab1, Christoph J Schlimp, Johannes Zipperle
1From the Ludwig Boltzmann Institute for Experimental and Clinical Traumatology (M.P., C.J.S., J.Z., H.R., H.S.), AUVA Research Centre; and Department of Anaesthesia, General Intensive Care and Pain Control (J.G.), Medical University of Vienna, Vienna; Red Cross Blood Transfusion Service for Upper Austria (C.G., S.S.), Linz; Department of Laboratory Medicine (J.C.), Paracelsus Medical University Salzburg; and Department of Anaesthesiology and Intensive Care (H.S.), AUVA Trauma Centre, Salzburg, Austria.
Background:
Platelet concentrates (PCs) are usually stored at room temperature under constant gentle agitation. Risk of bacterial contamination limits maximum storage time to 5 days. The objective of the study was to investigate platelet function with regard to storage time in different reconstituted whole blood (RWB) variants.
Methods:
Donated apheresis PCs were stored at 22°C over 5 days. To obtain RWB, apheresis PCs were mixed with plasma-free packed red blood cells (RBCs) and either prethawed fresh frozen plasma (PT) or solvent-detergent plasma (SD) [1:1:1 ratio], or with leukocyte- and platelet-depleted whole blood (LD-WB) as control. Platelet function in RWB variants was assessed by impedance aggregometry (Multiplate) on Days 0, 1, 3, and 5 following platelet donation.
Results:
Platelet aggregometry did not reach the lower limits determined from healthy volunteers in any of the RWB variants. Platelet aggregability measured by ASPI test, ADP test, and COL test declined over storage time in all RWB variants. No differences were observed in the TRAP test. At most measurement time points, LD-RWB provided significantly higher platelet aggregability compared with SD-RWB and PT-RWB (p < 0.01). SD-RWB demonstrated higher platelet aggregability on Day 0 in the ASPI test, ADP test, and TRAP test compared with PT-RWB.
Conclusion:
Apheresis PCs stored for 5 days at 22°C demonstrated reduced platelet aggregability, as measured by multiple electrode aggregometry when mixed with RBCs and plasma. As platelet aggregation in LD-RWB was superior compared with SD-RWB and PT-RWB variants, it might be possible that additives in RBCs or plasma are responsible for the observed depressed platelet function. Critical evaluation of current massive transfusion recommendations proposing early platelet transfusion is indicated.
Related Concept Videos
Structure and Function of Platelets
Platelets are continually replenished, circulating in the bloodstream for 9-12 days before being removed by phagocytes, primarily in the spleen. A microliter of circulating blood contains between 150,000 and 450,000...
Formation of the Platelet Plug
As the injured blood vessel contracts, endothelial cells undergo contraction, revealing collagen fibers in the basement membrane and underlying connective tissue. Furthermore, the plasma membrane of endothelial cells becomes adhesive, preparing the site for platelet adhesion. Platelets...
Clot Retraction and Fibrinolysis