Changes in Vascular Tone Occur Early During Hemodialysis Treatments Independently of Volume Reduction

Albert Power1, Evangelia Charitaki2, Andrew Davenport2

  • 1Richard Bright Renal Service, Southmead Hospital, North Bristol NHS Trust, Bristol, UK.

Artificial Organs
|October 27, 2015
PubMed

Hypotension commonly occurs during hemodialysis (HD). Hypotension can result from an absolute reduction in plasma volume following excessive ultrafiltration or from a reduction in vascular tone. We hypothesized that changes in vascular tone could occur during dialysis. Aortic pulse wave velocity (aPWV) was measured in 197 HD patients, mean age 63.3 ± 16.6 years, 62% male, 49% diabetic, during a single HD session. aPWV did not change (9.6 ± 2.2 vs. 9.6 ± 2.2 m/s) with HD. Systolic blood pressure (SBP) declined from 151 ± 31 to 147 ± 32 after 20 min and to 140 ± 36 mm Hg on completion of HD (P < 0.05), with an ultrafiltration volume of 2.2 ± 0.9 L over a 3.9 ± 0.4 h HD session. Aortic SBP declined from 154 ± 32 to 146 ± 29 after 20 min and 143 ± 35 at the end of HD, P < 0.001. Aortic augmentation index (Aortic Aix) decreased from 65% (52-79%) to 36.7% (23.3-52.9%) by 20 min and to 34.3 (15.1-49.1%) on completion of HD (P < 0.05), and brachial augmentation index (brachial Aix) from 5.7% (-25.2 to 27.5%) to -1.9% (-2.2 to 30.1%) and -6.6% (-44 to 22.7%), respectively, P < 0.05. Diastolic reflection area (DRA) increased from 36.7 (27.9-46.3) to 40.4 (32.2-51) after 20 min and 47.1 (34.2-60.5) on completion of HD, P < 0.05. We report changes in arterial tone within 20 min of starting HD, when minimal ultrafiltration has occurred, suggesting that volume changes may not be the only predisposing cause of intradialytic hypotension. The combination of a fall in SBP and a rise in DRA would suggest a reduction in coronary blood flow in keeping with reports of "myocardial stunning" during HD.

Related Concept Videos

Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
1.8K
Hemodialysis III: Nursing Management01:25

Hemodialysis III: Nursing Management

The nursing management of a patient undergoing hemodialysis includes several critical steps, starting with a thorough assessment before the procedure.Before the Hemodialysis ProcedureFirst, record the patient's vital signs—blood pressure, heart rate, respiratory rate, and temperature—to establish a baseline. This baseline is essential for detecting conditions such as hypotension that could impact the patient's response to dialysis. Document the patient's pre-dialysis weight, as this...
1.5K
Hemodialysis I: Introduction01:25

Hemodialysis I: Introduction

Hemodialysis (HD) is a medical treatment that artificially removes waste products, excess fluids, and toxins from the blood when the kidneys are no longer able to perform these functions effectively. In this process, blood is filtered through a semipermeable membrane, allowing for the selective removal of waste while preserving necessary components like blood cells and proteins. Hemodialysis is typically performed in patients with end-stage renal disease (ESRD) or severe kidney...
3.2K
Hypertension and Regulation of Blood Pressure01:18

Hypertension and Regulation of Blood Pressure

Hypertension, the most common cardiovascular disease, is diagnosed through repeated measurements of elevated blood pressure. Its risks, including damage to the kidney, heart, and brain, are directly proportional to blood pressure levels. Starting from 115/75 mm Hg, the risk of cardiovascular disease doubles with each increment of 20/10 mm Hg. The diagnosis relies on blood pressure measurements, not on patient symptoms, as hypertension is often asymptomatic until end-organ damage is imminent or...
4.8K
Dialysis01:27

Dialysis

Renal failure occurs when the kidneys lose their ability to filter waste products from the blood effectively. It can be classified into two types: acute renal failure (ARF) and chronic renal failure (CRF).
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
2.0K
Dialysis01:15

Dialysis

Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...
2.2K