Related Experiment Video
Updated: Mar 31, 2026

A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
(18)F-DOPA PET/CT in the diagnosis and localization of persistent medullary thyroid carcinoma
Aurélien Archier1,2, Céline Heimburger3, Carole Guerin4
1Department of Nuclear Medicine, La Timone University Hospital, Aix-Marseille University, Marseille, France.
Purpose:
To evaluate the performance of (18)F-L-dihydroxyphenylalanine ((18)F-DOPA) PET/CT in the detection of locoregional and distant medullary thyroid carcinoma (MTC) metastases and to compare imaging findings with histological data.
Methods:
We retrospectively evaluated 86 MTC patients with persistently high serum calcitonin levels after initial surgery who had undergone (18)F-DOPA PET/CT between January 2007 and December 2014 in two referral centres. They were followed up for at least 6 months after the PET/CT assessment. The results were compared with histological data or with the findings obtained during follow-up using a complementary imaging modality.
Results:
(18)F-DOPA PET/CT was positive in 65 of the 86 patients, corresponding to a patient-based sensitivity of 75.6 %. Distant metastatic disease (M1) was seen in 29 patients including 11 with previously unknown metastases revealed only by PET/CT. Among the 36 patients without distant metastatic spread, 25 had nodal involvement limited to the neck, and 10 of these 25 patients underwent reoperation. The lymph node compartment-based sensitivity of (18)F-DOPA PET/CT was 100 % in the two institutions but lesion-based sensitivity was only 24 %. Preoperative and postoperative median calcitonin levels were 405 pg/mL (range 128 - 1,960 pg/mL) and 259 pg/mL (range 33 - 1,516 pg/mL), respectively. None of the patients achieved normalization of serum calcitonin after reoperation.
Conclusion:
(18)F-DOPA PET/CT enables early diagnosis of a significant number of patients with distant metastasis. It has a limited sensitivity in the detection of residual disease but provides high performance for regional analysis. A surgical compartment-oriented approach could be the approach of choice whatever the number of nodes revealed by (18)F-DOPA PET/CT.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

