Related Experiment Video
Updated: Mar 31, 2026

An Atmospheric Pressure Plasma Setup to Investigate the Reactive Species Formation
Published on: November 3, 2016
Identification of oxygen-19 during in vivo neutron activation analysis of water phantoms
Syed N A Tahir1, David R Chettle
1Department of Medical Physics and Applied Radiation Sciences, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4KI, Canada.
Abstract:
Hand bone equivalent phantoms (250 ml) carrying selenium in various amounts were irradiated and counted for in vivo neutron activation analysis (IVNAA) by employing a 4π NaI(TI) based detection system. During the analysis of counting data, a feature at a higher energy than the gamma ray peak from (77m)Se (0.162 MeV) was observed at 0.197 MeV. Further investigations were made by preparing water phantoms containing only de-ionized water in 250 ml and 1034 ml quantities. Neutrons were produced by the (7)Li(p,n)(7)Be reaction using the high beam current Tandetron accelerator. Phantoms were irradiated at a fixed proton energy of 2.3 MeV and proton currents of 400 μA and 550 μA for 30 s and 22 s respectively. The counting data saved using the 4π NaI(TI) detection system for 10 s intervals in anticoincidence, coincidence and singles modes of detection were analyzed. Areas under gamma peaks at energies 0.197 MeV and 1.357 MeV were computed and half-lives from the number of counts for the two peaks were established. It was concluded that during neutron activation of water phantoms, oxygen-18 is activated, producing short-lived radioactive 19O having T(1/2) = 26.9 s. Induced activity from 19O may contribute spectral interference in the gamma ray spectrum. This effect may need to be taken into account by researchers while carrying out IVNAA of biological subjects.
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Absorption Spectroscopy: Atomization Methods
Other Nuclides: 31P, 19F, 15N NMR
While fluorine-19 and phosphorous-31 have high natural abundances (100%) and positive gyromagnetic ratios, nitrogen-15 has a low natural abundance and a negative gyromagnetic ratio. However, nitrogen-15 is still preferred over nitrogen-14 (which has a...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...

