For Narrow Networks, Fresh Scrutiny: Can They Pass the Adequacy Test?

Managed Care (Langhorne, Pa.)
|November 3, 2015
PubMed
Abstract

No abstract available in PubMed .

Related Concept Videos

Network Function of a Circuit01:25

Network Function of a Circuit

Frequency response analysis in electrical circuits provides vital insights into a circuit's behavior as the frequency of the input signal changes. The transfer function, a mathematical tool, is instrumental in understanding this behavior. It defines the relationship between phasor output and input and comes in four types: voltage gain, current gain, transfer impedance, and transfer admittance. The critical components of the transfer function are the poles and zeros.
995
Equivalent Resistance01:16

Equivalent Resistance

In circuit analysis, situations often arise where resistors are neither in series nor parallel configurations. To tackle such scenarios, three-terminal equivalent networks like the wye (Y) (Figure 1 (a)) or tee (T) and delta (Δ) (Figure 1 (b)) or pi (π) networks come into play. These networks offer versatile solutions and are frequently encountered in various applications, including three-phase electrical systems, electrical filters, and matching networks.
1.2K
Thevinin's Theorem01:15

Thevinin's Theorem

Thévenin's theorem plays a pivotal role in electrical circuit analysis, offering a solution to the challenges posed by variable loads within a circuit. In practical applications, it is common to encounter circuits where certain elements remain fixed while others fluctuate, often referred to as the "load." A typical household electrical outlet serves as a prime example of a variable load, as it can be connected to a variety of appliances, each with its own unique electrical characteristics.
1.9K
Routh-Hurwitz Criterion II01:19

Routh-Hurwitz Criterion II

In the application of the Routh-Hurwitz criterion, two specific scenarios can arise that complicate stability analysis.
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first...
1.2K
Norton Equivalent Circuits01:16

Norton Equivalent Circuits

Norton's theorem is a fundamental concept in the field of electrical engineering that allows for the simplification of complex AC circuits. The theorem states that any two-terminal linear network can be replaced with an equivalent circuit that consists of an impedance, which is parallel with a constant current source. Figure 1 shows the AC circuit portioned into two parts: Circuit A and Circuit B, while Figure 2 depicts the circuit obtained by replacing Circuit A by its Norton equivalent...
941
Routh-Hurwitz Criterion I01:15

Routh-Hurwitz Criterion I

Consider an electrical power grid, where stability is essential to prevent blackouts. The Routh-Hurwitz criterion is a valuable tool for assessing system stability under varying load conditions or faults. By analyzing the closed-loop transfer function, the Routh-Hurwitz criterion helps determine whether the system remains stable.
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
678