Diagnostic accuracy of fluorine-18-fluorodeoxyglucose positron emission tomography in gallbladder cancer: A meta-analysis
Related Experiment Video
Updated: Mar 30, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Salvatore Annunziata1, Daniele Antonio Pizzuto1, Carmelo Caldarella1
1Salvatore Annunziata, Daniele Antonio Pizzuto, Carmelo Caldarella, Institute of Nuclear Medicine, Department of Bioimaging and Radiological Sciences, Catholic University of the Sacred Heart, 00168 Rome, Italy.
Aim:
To meta-analyze published data about the diagnostic accuracy of fluorine-18-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (PET/CT) in the evaluation of primary tumor in patients with gallbladder cancer (GBCa).
Methods:
A comprehensive literature search of studies published through 30(th) June 2014 regarding the role of (18)F-FDG PET and PET/CT in the evaluation of primary gallbladder cancer (GBCa) was performed. All retrieved studies were reviewed. Pooled sensitivity and specificity of (18)F-FDG PET or PET/CT in the evaluation of primary GBCa were calculated. The area under the summary receiving operator characteristics curve (AUC) was calculated to measure the accuracy of these methods. Sub-analyses considering the device used (PET vs PET/CT) were carried out.
Results:
Twenty-one studies comprising 495 patients who underwent (18)F-FDG PET or PET/CT for suspicious GBCa were selected for the systematic review. The meta-analysis of 13 selected studies provided the following results: sensitivity 87% (95%CI: 82%-92%), specificity 78% (95%CI: 68%-86%). The AUC was 0.88. Improvement of sensitivity and specificity was observed when PET/CT was used.
Conclusion:
(18)F-FDG-PET and PET/CT demonstrated to be useful diagnostic imaging methods in the assessment of primary tumor in GBCa patients, nevertheless possible sources of false-negative and false-positive results should be kept in mind. PET/CT seems to have a better diagnostic accuracy than PET alone in this setting.
More Related Videos
08:42Using Multi-fluorinated Bile Acids and In Vivo Magnetic Resonance Imaging to Measure Bile Acid Transport
Published on: November 27, 2016
06:51Utilizing 18F-FDG PET/CT Imaging and Quantitative Histology to Measure Dynamic Changes in the Glucose Metabolism in Mouse Models of Lung Cancer
Published on: July 21, 2018
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...