Related Experiment Video
Updated: Mar 30, 2026

Intense Pulsed Light for the Treatment of Dry Eye Owing to Meibomian Gland Dysfunction
Published on: April 1, 2019
Influence of Meibomian Gland Expression Methods on Human Lipid Analysis Results
Carolina M E Kunnen1, Simon H J Brown2, Percy Lazon de la Jara1
1Brien Holden Vision Institute, Sydney, NSW, Australia; School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia; Vision Cooperative Research Centre, Sydney, NSW, Australia.
Purpose:
To compare the lipid composition of human meibum across three different meibum expression techniques.
Methods:
Meibum was collected from five healthy non-contact lens wearers (aged 20-35 years) after cleaning the eyelid margin using three meibum expression methods: cotton buds (CB), meibomian gland evaluator (MGE) and meibomian gland forceps (MGF). Meibum was also collected using cotton buds without cleaning the eyelid margin (CBn). Lipids were analyzed by chip-based, nano-electrospray mass spectrometry (ESI-MS). Comparisons were made using linear mixed models.
Results:
Tandem MS enabled identification and quantification of over 200 lipid species across ten lipid classes. There were significant differences between collection techniques in the relative quantities of polar lipids obtained (P<.05). The MGE method returned smaller polar lipid quantities than the CB approaches. No significant differences were found between techniques for nonpolar lipids. No significant differences were found between cleaned and non-cleaned eyelids for polar or nonpolar lipids.
Conclusion:
Meibum expression technique influences the relative amount of phospholipids in the resulting sample. The highest amounts of phospholipids were detected with the CB approaches and the lowest with the MGE technique. Cleaning the eyelid margin prior to expression was not found to affect the lipid composition of the sample. This may be a consequence of the more forceful expression resulting in cell membrane contamination or higher risk of tear lipid contamination as a result of reflex tearing.