Related Experiment Video
Updated: Mar 30, 2026

Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
Effect of decontamination on micro-shear bond strength of silorane-based composite increments
Seyedeh Mahsa Sheikh-Al-Eslamian1, Narges Panahandeh1, Ahmad Najafi-Abrandabadi1
1Dental Research Center, Research Institute of Dental Sciences, Dental School, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Aim:
The aim of the present study was to evaluate the micro-shear bond strength of silorane-based composites after saliva/blood decontamination.
Methods:
A transparent mold (1 × 2 × 1 cm) was used to make 11 flat, silorane-based composite blocks. One block served as the control. After contamination, the blocks were treated as follows: group 1: 10-s air spray; group 2: 10-s water spray + 10-s air spray; group 3: 10-s water spray + 10-s air spray + 10-s etching with phosphoric acid; group 4: 10-s air spray + 10-s etching + bonding; group 5: 10-s water spray + 10-s air spray + 10-s etching + bonding; and groups 6-10: treated the same as groups 1-5, the only difference being that blood was used instead of saliva. Ten tubes (0.7 mm × 1 mm) containing silorane-based composites were attached to each decontaminated block and light cured for 40 s. After 24-h storage in distilled water, specimens were tested under micro-shear loading at a cross-head speed of 0.5 mm/min. Data were analyzed using one-way anova and Tukey's honest significant difference (HSD) test (P < 0.05).
Results:
One-way anova showed significant differences in the micro-shear bond strength among the experimental groups (P < 0.001). Tukey's HSD test revealed that the bond strengths in groups 5, 9, and 10 were similar to the control group (P > 0.05).
Conclusion:
Decontamination by water and air spray, etching, and bonding was effective in restoring the bond strength of silorane-based composite increments.
More Related Videos
06:36Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
Published on: March 14, 2025
03:10Pilot In Vitro Study to Assess Cleaning Ability and Effects of Different Decontamination Methods on Implant Surfaces
Published on: November 21, 2025