Related Experiment Video
Updated: Mar 30, 2026

Development of a Preclinical Inhalation Model to Test Vaporized Cannabis Distillates
Published on: May 30, 2025
Development of an inhalation unit risk factor for isoprene
Joseph T Haney1, Tracie Phillips1, Robert L Sielken2
1Texas Commission on Environmental Quality (TCEQ), Toxicology Division, MC-168, P.O. Box 13087, Austin, TX 78711, United States.
Abstract:
A unit risk factor (URF) was developed for isoprene based on evaluation of three animal studies with adequate data to perform dose-response modeling (NTP, 1994, 1999; Placke et al., 1996). Ultimately, the URF of 6.2E-08 per ppb (2.2E-08 per μg/m(3)) was based on the 95% lower confidence limit on the effective concentration corresponding to 10% extra risk for liver carcinoma in male B6C3F1 mice after incorporating appropriate adjustment factors for species differences in target tissue metabolite concentrations and inhalation dosimetry. The corresponding lifetime air concentration at the 1 in 100,000 no significant excess risk level is 160 ppb (450 μg/m(3)). This concentration is almost 4400 times lower than the lowest exposure level associated with statistically increased liver carcinoma in B6C3F1 mice in the key study (700 ppm in Placke et al., 1996) and is above typical isoprene breath concentrations reported in the scientific literature. Continuous lifetime environmental exposure to the 1 in 100,000 excess risk level of 160 ppb would be expected to raise the human blood isoprene area under the curve (AUC) less than one-third of the standard deviation of the endogenous mean blood AUC. The mean for ambient air monitoring sites in Texas (2005-2014) is approximately 0.13 ppb.
More Related Videos
05:07Development of a Nose-only Inhalation Toxicity Test Chamber That Provides Four Exposure Concentrations of Nano-sized Particles
Published on: March 18, 2019
09:29An Air-liquid Interface Bronchial Epithelial Model for Realistic, Repeated Inhalation Exposure to Airborne Particles for Toxicity Testing
Published on: May 13, 2020
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Chronic Obstructive Pulmonary Disease-I: Introduction
Inhalational Anesthetics: Overview
Asthma-I: Introduction
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Chronic Obstructive Pulmonary Disease-II: Pathophysiology
Chronic Inflammation