Related Experiment Video
Updated: Mar 30, 2026

Applicability Analysis of Assessment Methods for Morphological Parameters of Corroded Steel Bars
Published on: November 1, 2018
Tight Placement of Erich Arch Bar While Avoiding Wire Fatigue Failure
Daniel Kirk1, Joseph Whitney2, David Shafer3
1Fourth-Year Dental Student, University of Connecticut School of Dental Medicine, Farmington, CT.
Optimizing Erich arch bar application, this study found that a 45° wire angle reduces twists to tightness and increases resistance to failure. Experienced surgeons benefit from a 5mm grasp, while novices gain from a 10mm grasp for better over-twisting tolerance.
Area of Science:
- Orthodontics
- Biomaterials Science
- Surgical Techniques
Background:
- Erich arch bars are crucial for maxillofacial fracture fixation.
- Proper wire tensioning is vital for arch bar stability and preventing complications.
- Understanding wire fatigue is essential for optimizing surgical outcomes.
Purpose of the Study:
- To determine the optimal number of wire twists for Erich arch bar tightness.
- To evaluate the impact of grasping distance and angle on wire twists to failure.
- To provide data for improving the efficiency and success of arch bar application.
Main Methods:
- Simulated surgical placement of 24- and 26-gauge wires for arch bars.
- Varied wire grasping distances (5 vs 10 mm) and angles (45° vs 90°).
- Assessed twists to tightness and failure, wire fatigability via shearing tests, and visualized wire morphology using electron microscopy.
Main Results:
- Fewer twists to tightness and greater resistance to failure were observed at a 45° angle for both wire gauges.
- A 5mm grasping distance required fewer twists for tightness but showed varied resistance to failure.
- Electron microscopy confirmed wire fatigue at 90° angles after overtightening, but not at 45°.
Conclusions:
- A 45° wire angle is recommended for 24-gauge wires to achieve tightness with fewer twists and enhanced resistance to failure.
- A 5mm grasping distance is suitable for experienced surgeons, while 10mm is recommended for novices due to increased tolerance for over-twisting.
More Related Videos
Related Concept Videos
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used...
Yield Criteria for Ductile Materials under Plane Stress
The Maximum Shearing Stress Criterion, also known as...
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...
Fatigue
Temperature Dependent Deformation
Torsion of Noncircular Members