Related Experiment Video
Updated: Mar 30, 2026

ELIME Enzyme Linked Immuno Magnetic Electrochemical Method for Mycotoxin Detection
Published on: October 23, 2009
Sensitive electrochemical immunoassay for chlorpyrifos by using flake-like Fe3O4 modified carbon nanotubes as the
Zihong Sun1, Weihua Wang2, Haibin Wen1
1Institute of Biomaterials, College of Materials & Energy, South China Agricultural University, Guangzhou 510642, China.
Abstract:
A highly sensitive electrochemical immunoassay of chlorpyrifos (CPF) was developed by using a biocompatible quinone-rich polydopamine nanospheres modified glass carbon electrode as the sensor platform and multi-horseradish peroxidase-flake like Fe3O4 coated carbon nanotube nanocomposites as the signal label. Due to the quinone-rich polydopamine nanospheres, the platform exhibited excellent fixing capacity by simple coating of sticky polydopamine nanospheres and subsequent oxidization. By coprecipitation of Fe(3+) and Fe(2+) on polydopamine modified carbon nanotubes (CNTs) with the aid of ethylene glycol (EG), the flake-like Fe3O4 coated CNTs (CNTs@f-Fe3O4) were synthesized and chosen as the carrier of multi-enzyme label due to the high loading of secondary antibody (Ab2) and horseradish peroxidase (HRP) and also the peroxidase-mimic activity of Fe3O4. Under the optimum conditions, the immunosensor can detect CPF over a wide range with a detection limit of 6.3 pg/mL. Besides, the high specificity, reproducibility and stability of the proposed immunosensor were also proved. The preliminary application in real sample showed good recoveries, indicating it holds promise for fast analysis of CPF in aquatic environment.