Measurements of Elliptic and Triangular Flow in High-Multiplicity 3He+Au Collisions at (s(NN))=200 GeV

A Adare1, S Afanasiev2, C Aidala3,4,5,6

  • 1University of Colorado, Boulder, Colorado 80309, USA.

Physical Review Letters
|November 10, 2015
PubMed

Related Concept Videos

Eulerian and Lagrangian Flow Descriptions01:22

Eulerian and Lagrangian Flow Descriptions

Fluid flow analysis is critical in many scientific and engineering disciplines, and two principal approaches are used to describe this flow: the Eulerian and Lagrangian methods. These methods offer different perspectives on monitoring and analyzing the motion of fluids, each with distinct advantages depending on the scenario.
The Eulerian method focuses on fixed points in space where fluid properties, such as velocity, pressure, and temperature, are observed as the fluid moves between these...
2.1K
Uniform Depth Channel Flow01:27

Uniform Depth Channel Flow

Uniform depth channel flow keeps fluid depth consistent along channels such as irrigation canals. In natural channels, such as rivers, approximate uniform flow is often assumed. This condition occurs when the channel’s bottom slope matches the energy slope, balancing potential energy lost from gravity with head loss due to shear stress. This balance prevents depth changes along the channel length, resulting in a steady, uniform flow.Uniform flow in open channels with a constant cross-section...
743
Measurement of Fluid Pressure01:16

Measurement of Fluid Pressure

Fluid pressure is commonly measured using devices called manometers, which rely on liquid columns to indicate pressure differences. The height of a liquid column in a manometer reflects the pressure exerted by the fluid, providing a simple yet effective means of measurement. Different types of manometers serve specific purposes based on their configurations and the type of fluids involved.
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
2.2K
Steady, Laminar Flow in Circular Tubes01:23

Steady, Laminar Flow in Circular Tubes

Hagen-Poiseuille flow describes a viscous fluid's steady, incompressible flow through a cylindrical tube with a constant radius R. This flow profile is often applied to understand fluid transport in narrow channels, such as capillaries. It serves as a foundational example of laminar flow. In this model, cylindrical coordinates (r,θ,z) are used to describe the radial (r), angular (θ), and axial (z) dimensions within the tube. For Hagen-Poiseuille flow, the velocity profile is purely axial,...
1.4K
Couette Flow01:22

Couette Flow

Couette flow represents the flow of fluid between two parallel plates, with one plate fixed and the other moving with a constant velocity. This configuration allows for a simplified analysis using the Navier-Stokes equations, which govern fluid motion under conditions of viscosity and incompressibility. For Couette flow, the assumptions include a steady, laminar, incompressible flow with a zero-pressure gradient in the flow direction. This flow type is beneficial for understanding shear-driven...
1.3K